Skip to main content
Schneider Electric A9N21361

Schneider Electric A9N21361 DT40N MCB, 2 A, Curve C, 1P+N

MPN A9N21361
Obsolete

Schneider Electric ProDis DT40N, MCB, 2 A, curve C, 1P+N, 6 kA Icn per EN/IEC 60898-1, 10 kA Icu per IEC 60947-2, clip-on DIN rail, IP20, white.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N21361 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230 V AC 50 Hz between phase and neutral
Insulation voltage ui400 V AC 50 Hz
Breaking capacity6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 60898-1 10 kA Icu at 230...240 V AC 50 Hz conforming to IEC 60947-2
IP ratingIP20
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...70 °C

All specifications

A9N21361 additional specifications
ParameterValue
Pollution degree3 conforming to IEC 60947-2
ColorWhite
Depth78 mm
Width18 mm
Height81 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

It protects a single pole plus neutral (1P+N) and is designed for distribution boards on 50 Hz AC networks. Breaking capacity is 6 kA Icn at 230 V AC per EN/IEC 60898-1, and 10 kA Icu at 230–240 V AC per IEC 60947-2 — enough for most residential and light commercial service-entrance panels where the upstream transformer impedance limits fault current.

Curve C means the magnetic trip operates at 5 to 10 times rated current (10–20 A for this 2 A unit). For high-inrush loads (transformers, large motors) a D curve would be needed. Thermal-magnetic trip technology combines a bimetal strip for overload protection and a solenoid for short-circuit. The 20,000-cycle electrical and mechanical endurance matches the duty expected in a distribution board that sees occasional switching, not daily load-break. Pollution degree 3 (IEC 60947-2) and overvoltage category IV mean the breaker is rated for the harsh electrical environment of a main distribution panel — not just downstream sub-circuits. Tropicalisation class 2 (IEC 60068-1) adds humidity tolerance up to 95% RH at 55 °C.

MPN
A9N21361