Skip to main content
Schneider Electric A9N21541

Schneider Electric A9N21541 iDPN MCB, 40A, 1P+N, B Curve, 4.

MPN A9N21541
Obsolete

Schneider Electric Clario iDPN miniature circuit breaker, A9N21541, 40 A, 1P+N, B curve, 4.5 kA breaking capacity at 230 V AC, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N21541 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230 V AC 50/60 Hz between phase and neutral
Insulation voltage ui400 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity4500 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...70 °C

All specifications

A9N21541 additional specifications
ParameterValue
Pollution degree3 conforming to IEC 60947-1
ColorWhite
Depth78 mm
Width18 mm
Height81 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

It breaks fault currents up to 4500 A Icn at 230 V AC (50/60 Hz) per EN/IEC 60898-1.

The B curve (magnetic trip at 3...5 x In) means it trips instantaneously between 120 A and 200 A. That's the standard choice for resistive loads and general-purpose socket circuits where inrush is low — lighting, heaters, small office outlets. If you're protecting motor circuits or transformers with higher inrush, a C or D curve would be the better pick; this one will nuisance-trip on those loads. The 1P+N configuration switches the phase and provides a switched neutral that opens with the phase. That's common in single-phase final circuits where you want the neutral isolated when the breaker is off — typical in UK and European distribution boards. Thermal-magnetic trip technology covers both overload (thermal bimetal, slower response) and short-circuit (magnetic coil, instantaneous). IP20 finger-safe terminals are fine for enclosed boards; not rated for wet or dusty environments.

Integration notes

Tunnel-type terminals accept 0.75...16 mm² rigid or 0.33...10 mm² flexible on both line and load sides. Strip length 13 mm. That's enough for a 6 mm² feed into a 40 A circuit — typical for a cooker or shower circuit in domestic boards. Mechanical durability is 20000 cycles, electrical durability 10000 cycles — that's the rated number of on/off operations under load before wear-out. Fine for a distribution board that sees infrequent switching; not a switch-disconnector for daily operation. Suitable for isolation (marked with the isolation symbol on the device), so it can be used as a disconnecting means for the downstream circuit during maintenance, provided the supply side is de-energised or the breaker is off and locked out.

MPN
A9N21541