Skip to main content
Schneider Electric A9N21558

Schneider Electric A9N21558 iDPN N MCB, 20 A C-Curve 1P+N, 1

MPN A9N21558
Obsolete

Schneider Electric Clario iDPN N miniature circuit breaker, A9N21558, 20 A rated, C-curve, 1P+N, 10 kA breaking capacity at 230 V AC, dual-standard certified EN/IEC 60898-1 and IEC 60947-2, DIN-rail clip-on mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N21558 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230 V AC 50/60 Hz between phase and neutral
Insulation voltage ui400 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Pollution degree3 conforming to IEC 60947-1

All specifications

A9N21558 additional specifications
ParameterValue
ColorWhite
Depth78 mm
Width18 mm
Height81 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

It carries dual certification to EN/IEC 60898-1 for household-type protection and IEC 60947-2 for industrial isolation duty, giving it a 10 kA breaking capacity at 230 V AC under the 60947-2 standard.

The 20 A rated current (In) matches standard branch-circuit protection for lighting, socket outlets, or small appliance loads on a 20 A circuit. Breaking capacity of 10 kA Icu at 230 V AC under IEC 60947-2 means this breaker can safely interrupt fault currents up to 10,000 A without welding its contacts or rupturing the case. The dual standard lets you specify it for either a domestic DB or an industrial sub-distribution board. Thermal-magnetic trip technology uses a bimetal strip for overload protection and a solenoid for short-circuit response. The thermal element tracks the load current continuously; the magnetic element reacts to the instantaneous peak. This is the standard, field-proven trip mechanism for general-purpose MCBs.

Clip-on mounting to a standard 35 mm DIN rail (EN 60715) with a 18 mm width per module — the 1P+N occupies two 9 mm pitches. Neutral is on the left, phase on the right. Toggle control with ON/OFF indication on the front face. Tunnel-type terminals accept 0.33–10 mm² flexible or 0.75–16 mm² rigid conductors, with a tightening torque of 2 N.m and a wire stripping length of 13 mm. IP20 finger-safe protection for panel installation.

MPN
A9N21558