Schneider Electric A9N26596

A9N26596 Vigi xC60 Add-on RCD, 4P 25A AC 100mA

MPN A9N26596
Active

Schneider Electric Acti9 Vigi xC60 add-on residual current device, 4P, 25 A, Type AC, 100 mA, 400-415 V AC, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N26596 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage400...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 400...415 V conforming to EN/IEC 61009-2-1
Insulation voltage ui500 V AC 50/60 Hz
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...85 °C
Pollution degree3
Depth74.5 mm
Width126 mm
Height87 mm
Operating temperature-5...60 °C

Product details

The Schneider A9N26596 is an Acti9 Vigi xC60 add-on residual current device (RCD) — a 4-pole block that clips onto the outgoing side of a compatible MCB to add earth-leakage protection. It's rated 25 A, 400-415 V AC, with a 100 mA sensitivity and Type AC waveform detection. That 100 mA trip threshold means it's sized for general fault protection, not personnel shock prevention (which needs 30 mA or lower). On a 25 A outgoing circuit — lighting, general socket outlets, small distribution — it catches insulation faults and equipment leakage before they escalate.

Clip-on mount to DIN rail, 6 x 9 mm module pitches wide (126 mm). It's an add-on block — screws onto the load side of a compatible Acti9 MCB, no extra wiring between them. The tunnel terminals on the bottom accept 1-25 mm² rigid or 1-16 mm² flexible, stripped 14 mm, torqued to 2 N·m.

Electrical behaviour and standards

Voltage-independent electromechanical trip — no auxiliary power needed to detect the fault. Instantaneous response (no intentional time delay), so it's the fast-trip layer in a selective coordination scheme. Rated insulation voltage 500 V AC, impulse withstand 6 kV, and it shrugs off 8/20 µs surge currents up to 250 A without nuisance tripping. Built to EN/IEC 61009-1 and 61009-2-1, pollution degree 3, for 50/60 Hz AC networks. The red indicator on the front shows tripped status at a glance.