Skip to main content
Schneider Electric A9N26613

A9N26613 Vigi xC60 Add-on RCD, 2P 63A 300mA AC, Obsolete

MPN A9N26613
Obsolete

Schneider Electric Acti9 Vigi xC60 add-on residual current device, A9N26613, 2P, 63 A, 300 mA, Type AC, instantaneous, voltage-independent electromechanical, clip-on DIN rail mount, IP20/IP40.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N26613 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage230...240 V AC 50/60 Hz conforming to EN/IEC 61009-1 230...240 V conforming to EN/IEC 61009-2-1
Insulation voltage ui500 V AC 50/60 Hz
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...85 °C
Pollution degree3
Depth74.5 mm
Width72 mm
Height87 mm
Operating temperature-5...60 °C

Product details

The A9N26613 is a Vigi xC60 add-on residual current device from the Acti9 range, designed to clip onto the outgoing side of a compatible MCB to provide earth leakage protection. The tripping mechanism is voltage-independent electromechanical, so it clears a ground fault even if the phase voltage collapses.

The 63 A rated current and 300 mA sensitivity set the protection threshold for the outgoing circuit. Type AC earth leakage protection covers sinusoidal AC residual currents — standard for general-purpose socket circuits, lighting, and resistive loads, but not for loads with power electronics that generate pulsed or DC fault currents. The instantaneous time delay means it trips without intentional delay, so it coordinates with upstream time-delayed RCDs only if the upstream device has a higher rating or a deliberate S-type delay. The 6 kV impulse withstand voltage (Uimp) and pollution degree 3 rating confirm it is suitable for fixed installations in environments with conductive pollution, typical of distribution boards and industrial control panels.

Clip-on mounting on DIN rail, 4 modules wide at 9 mm pitch (72 mm total). The bottom tunnel terminals accept 1...35 mm² rigid or 1...25 mm² flexible conductors; strip length is 14 mm, tightening torque 3.5 N.m. Electrical connection to the upstream MCB is by screws — it physically couples to the outgoing side of a compatible Acti9 MCB, forming a combined RCBO assembly. The red indicator on the front face shows tripped status. IP20 on the body, IP40 inside the modular enclosure — suitable for dry indoor panel environments.

MPN
A9N26613