Schneider Electric A9N26644

Schneider Electric A9N26644 Vigi xC60 Add-on RCD, 4P 63A 100

MPN A9N26644
Active

Schneider Electric Acti9 Vigi xC60 add-on residual current device, A9N26644, 4P, 63 A, 100 mA sensitivity, Type AC, instantaneous, clip-on DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N26644 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage400...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 400...415 V conforming to EN/IEC 61009-2-1
Insulation voltage ui500 V AC 50/60 Hz
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...85 °C
Pollution degree3
Depth74.5 mm
Width135 mm
Height87 mm
Operating temperature-5...60 °C

Product details

The Schneider Electric A9N26644 is a Vigi xC60 add-on residual current device (RCD) from the Acti9 range, designed to clip onto the outgoing side of a compatible MCB or RCBO. It adds earth-leakage protection to an existing circuit breaker without replacing the whole device — a clean way to retrofit ground-fault protection into a panel that already has standard overcurrent protection. Rated at 63 A with 100 mA sensitivity, Type AC (sinusoidal AC residual currents only), it handles the common residential and light-commercial loads where the leakage path is purely sinusoidal. The 4-pole version (4P) suits three-phase outgoers, with the neutral pole switched as well. The voltage-independent electromechanical trip means it clears a fault even if the neutral is lost upstream — no electronics to starve.

The 63 A rated current (In) matches the upstream MCB's rating; you pair this RCD with a 63 A breaker on the same outgoing circuit. The 100 mA sensitivity is less sensitive than the common 30 mA for personal shock protection — it is sized for equipment protection or for circuits where a 30 mA device would nuisance-trip (e.g., long cable runs with natural leakage). If the load includes rectifiers, VFDs, or switched-mode supplies that generate pulsed DC or high-frequency leakage, you need Type A or Type B instead. For purely resistive or induction-motor loads with no electronic front end, Type AC is sufficient and costs less. The instantaneous trip (no intentional delay) clears a fault within tens of milliseconds. That is fine for most circuits but may cause coordination issues if you have downstream RCDs — you would need a time-delayed (S-type) device upstream to avoid simultaneous tripping. Insulation voltage is 500 V AC, and impulse withstand is 6 kV — enough for typical distribution panels without additional surge protection.

Clip-on mounting onto a DIN rail — no tools needed for the rail itself. Strip length 14 mm. Electrical connection to the upstream MCB is by screws (the add-on block bolts directly to the breaker's outgoing terminals). The red indicator on the front face shows when the RCD has tripped — useful for troubleshooting a downstream fault without metering. IP20 on the body (finger-safe), IP40 inside the modular enclosure — standard for indoor distribution boards.