Skip to main content
Schneider Electric A9N2P04CIN

Schneider Electric A9N2P04CIN Acti9 xC60 MCB, 4 A C-Curve 2P

MPN A9N2P04CIN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N2P04CIN, 4 A rated current, C-curve, 2-pole, 10 kA breaking capacity at 400 V AC, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N2P04CIN key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 100...125 V DC
Insulation voltage ui500 V AC 50/60 Hz conforming to IS/IEC 60947-2
Breaking capacity10 kA Inc at 380...415 V AC 50/60 Hz conforming to IS/IEC 60947-2 6 kA Icu at 100...125 V DC conforming to IS/IEC 60947-2
Utilization categoryCategory A conforming to IS/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C

All specifications

A9N2P04CIN additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3
ColorWhite
Depth77.5 mm
Width36 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric A9N2P04CIN is an Acti9 xC60 miniature circuit breaker rated at 4 A with a C-curve thermal-magnetic trip unit, meaning it holds 4 A continuous and trips magnetically between 5 and 10 times rated current — standard for general-purpose distribution protecting lighting, socket circuits, and small motor loads in commercial or residential panels. The 10 kA breaking capacity at 380–415 V AC (conforming to IS/IEC 60947-2) means it can safely interrupt a fault current up to that level without welding contacts or cascading upstream — adequate for most building supply points where the prospective short-circuit current stays under 10 kA. The 2-pole configuration (2P) switches both phase and neutral, giving full isolation on the outgoing circuit.

Panel integration and installation notes

The breaker occupies 36 mm width (2 x 18 mm modular pitches), which is two standard DIN-rail module spaces — plan for that when laying out a crowded panel.

MPN
A9N2P04CIN