Skip to main content
Schneider Electric A9N2P10DGN

Schneider Electric A9N2P10DGN Acti9 xC60 MCB, 10A D Curve 2P

MPN A9N2P10DGN
Active

Schneider Electric Acti9 xC60 series, A9N2P10DGN miniature circuit breaker, 2P, 10 A, D curve, 10 kA Icn at 415 V AC, clip-on 35 mm DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N2P10DGN key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz
Breaking capacity10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz conforming to IS/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9N2P10DGN additional specifications
ParameterValue
ColorWhite
Depth77.5 mm
Width36 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric A9N2P10DGN is a 2-pole miniature circuit breaker from the Acti9 xC60 family, rated 10 A with a D tripping curve. It protects final subcircuits against overload and short-circuit in AC distribution boards, per IS/IEC 60898-1. The D curve means magnetic tripping occurs at 10 to 14 times rated current (100–140 A instantaneous), so it handles the inrush of motor loads, transformers, or welding equipment without nuisance trips. For a 10 A breaker, that's a solid 100–140 A magnetic pickup — sized for high-starting-current circuits. Breaking capacity is 10 kA Icn at both 240 V and 415 V AC (50/60 Hz), certified to IS/IEC 60898-1.

Occupies two pole positions in a standard distribution board. Height 85 mm, depth 77.5 mm — fits flush in a residential or commercial enclosure with a transparent door. Biconnect feature allows daisy-chaining outgoing circuits without a separate distribution block.

Thermal-magnetic trip unit: the thermal bimetal protects against sustained overload (heating), the solenoid handles short-circuit. Rated operational voltage 220–240 V AC or 380–415 V AC, 50/60 Hz. Overvoltage category IV — suitable for main incoming supply at the service entrance, not just downstream subcircuits. Electrical and mechanical durability both rated at 20,000 cycles — typical for a distribution MCB; not intended for frequent switching duty (use a contactor or switch-disconnector for that). Earth-leakage protection requires a separate RCCB block (not integrated). The MCB itself provides overcurrent and short-circuit protection only.

MPN
A9N2P10DGN