Schneider Electric A9N2P10DGN — 2-Pole MCB (DIN Rail)

Schneider Electric A9N2P10DGN Acti9 xC60 MCB, 10A D Curve 2P

MPNA9N2P10DGN
Active

Schneider Electric Acti9 xC60 series, A9N2P10DGN miniature circuit breaker, 2P, 10 A, D curve, 10 kA Icn at 415 V AC, clip-on 35 mm DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9N2P10DGN — Identification
ParameterValue
Product nameXC60
Product rangeActi9
Series / familyActi9
Device short namexC60
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9N2P10DGN — Electrical
ParameterValue
Rated current [In]10 A
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
A9N2P10DGN — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit10...14 x In
Breaking capacity (Icu)10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz conforming to IS/IEC 60898-1
Energy limitation class3 conforming to IS/IEC 60898-1
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9N2P10DGN — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height85 mm
Depth77.5 mm
Mounting support35 mm DIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Terminal tightening torque2 N.m
Comb busbar / distribution block compatibilityTop: YES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
A9N2P10DGN — Environmental
ParameterValue
Operating temperature range-30...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9N2P10DGN — Approvals
ParameterValue
Standards / complianceIS/IEC 60898-1

Product details

The Schneider Electric A9N2P10DGN is a 2-pole miniature circuit breaker from the Acti9 xC60 family, rated 10 A with a D tripping curve. It protects final subcircuits against overload and short-circuit in AC distribution boards, per IS/IEC 60898-1. The D curve means magnetic tripping occurs at 10 to 14 times rated current (100–140 A instantaneous), so it handles the inrush of motor loads, transformers, or welding equipment without nuisance trips. For a 10 A breaker, that's a solid 100–140 A magnetic pickup — sized for high-starting-current circuits. Breaking capacity is 10 kA Icn at both 240 V and 415 V AC (50/60 Hz), certified to IS/IEC 60898-1.

Occupies two pole positions in a standard distribution board. Height 85 mm, depth 77.5 mm — fits flush in a residential or commercial enclosure with a transparent door. Biconnect feature allows daisy-chaining outgoing circuits without a separate distribution block.

Thermal-magnetic trip unit: the thermal bimetal protects against sustained overload (heating), the solenoid handles short-circuit. Rated operational voltage 220–240 V AC or 380–415 V AC, 50/60 Hz. Overvoltage category IV — suitable for main incoming supply at the service entrance, not just downstream subcircuits. Electrical and mechanical durability both rated at 20,000 cycles — typical for a distribution MCB; not intended for frequent switching duty (use a contactor or switch-disconnector for that). Earth-leakage protection requires a separate RCCB block (not integrated). The MCB itself provides overcurrent and short-circuit protection only.

Frequently asked questions

What is the breaking capacity of A9N2P10DGN?

The A9N2P10DGN has a breaking capacity of 10,000 A Icn at both 240 V AC and 415 V AC (50/60 Hz), certified to IS/IEC 60898-1.

What compliance documentation does Schneider provide for A9N2P10DGN?

The A9N2P10DGN is certified to IS/IEC 60898-1. It carries tropicalisation class 2 per IEC 60068-1. For RoHS, REACH, and other compliance documentation, request the manufacturer's declaration at quote time.