Skip to main content
Schneider Electric A9N2P16CGN

Schneider Electric A9N2P16CGN Acti9 xC60 MCB, 16 A, C-Curve

MPN A9N2P16CGN
Active

Schneider Electric Acti9 xC60, miniature circuit-breaker, 2P, 16 A, C-curve, 10 kA Icn at 240 V AC, clip-on 35 mm DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N2P16CGN key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz
Breaking capacity10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz conforming to IS/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9N2P16CGN additional specifications
ParameterValue
ColorWhite
Depth77.5 mm
Width36 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric A9N2P16CGN is an Acti9 xC60 miniature circuit-breaker — 2-pole, 16 A rated current, C-curve, with a 10 kA breaking capacity at 240 V AC per IS/IEC 60898-1. It clips onto a 35 mm DIN rail, making it a standard panel fit for distribution boards in commercial and light industrial builds.

C-curve and breaking capacity — what they mean for your board

The C-curve (magnetic trip at 5–10 × In) means this breaker handles moderate inrush from motor starters, small transformers, and lighting ballasts without nuisance tripping — typical for general distribution. The 16 A rating on 2 poles protects both phase and neutral in a single module, saving rail space. Breaking capacity of 10 kA at 240 V AC (also 10 kA at 415 V AC) is the fault current it can safely interrupt without welding or arcing through the enclosure. That rating meets the IS/IEC 60898-1 standard for domestic and commercial panels; if your available fault current exceeds 10 kA at the board, you need an upstream current-limiting device or a higher-rated breaker.

Panel fit and wiring

Clip-on mounting on 35 mm DIN rail, 36 mm wide (4 × 9 mm pitches). Tunnel terminals accept up to 25 mm² rigid or 16 mm² flexible; strip length 13 mm. Tightening torque 2 N·m. IP20 finger-safe front, pollution degree 3 — fine for a clean indoor panel, not for washdown zones.

MPN