Skip to main content
Schneider Electric A9N2P16CGN — 2-Pole MCB (DIN Rail)

Schneider Electric A9N2P16CGN Acti9 xC60 MCB, 16 A, C-Curve

MPNA9N2P16CGN
Active

Schneider Electric Acti9 xC60, miniature circuit-breaker, 2P, 16 A, C-curve, 10 kA Icn at 240 V AC, clip-on 35 mm DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9N2P16CGN — Identification
ParameterValue
Product nameXC60
Product rangeActi9
Series / familyActi9
Device short namexC60
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9N2P16CGN — Electrical
ParameterValue
Rated current [In]16 A
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
A9N2P16CGN — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu)10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz conforming to IS/IEC 60898-1
Energy limitation class3 conforming to IS/IEC 60898-1
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9N2P16CGN — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height85 mm
Depth77.5 mm
Mounting support35 mm DIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Terminal tightening torque2 N.m
Comb busbar / distribution block compatibilityTop: YES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
A9N2P16CGN — Environmental
ParameterValue
Operating temperature range-30...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9N2P16CGN — Approvals
ParameterValue
Standards / complianceIS/IEC 60898-1

Product details

The Schneider Electric A9N2P16CGN is an Acti9 xC60 miniature circuit-breaker — 2-pole, 16 A rated current, C-curve, with a 10 kA breaking capacity at 240 V AC per IS/IEC 60898-1. It clips onto a 35 mm DIN rail, making it a standard panel fit for distribution boards in commercial and light industrial builds.

C-curve and breaking capacity — what they mean for your board

The C-curve (magnetic trip at 5–10 × In) means this breaker handles moderate inrush from motor starters, small transformers, and lighting ballasts without nuisance tripping — typical for general distribution. The 16 A rating on 2 poles protects both phase and neutral in a single module, saving rail space. Breaking capacity of 10 kA at 240 V AC (also 10 kA at 415 V AC) is the fault current it can safely interrupt without welding or arcing through the enclosure. That rating meets the IS/IEC 60898-1 standard for domestic and commercial panels; if your available fault current exceeds 10 kA at the board, you need an upstream current-limiting device or a higher-rated breaker.

Panel fit and wiring

Clip-on mounting on 35 mm DIN rail, 36 mm wide (4 × 9 mm pitches). Tunnel terminals accept up to 25 mm² rigid or 16 mm² flexible; strip length 13 mm. Tightening torque 2 N·m. IP20 finger-safe front, pollution degree 3 — fine for a clean indoor panel, not for washdown zones.

Frequently asked questions

Where can I buy A9N2P16CGN?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.

What standard does A9N2P16CGN comply with?

It complies with IS/IEC 60898-1, the standard for miniature circuit-breakers for overcurrent protection in household and similar installations.

What is the breaking capacity of A9N2P16CGN?

10 kA Icn at 240 V AC and 10 kA Icn at 415 V AC, both per IS/IEC 60898-1.

MPN