Skip to main content
Schneider Electric A9N2P50CGN

Schneider Electric A9N2P50CGN Acti9 xC60 MCB, 50 A, C-Curve,

MPN A9N2P50CGN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N2P50CGN, 50 A, C-curve, 2-pole, 10 kA breaking capacity, 36 mm wide, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N2P50CGN key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...85 °C
Pollution degree3
ColorWhite

All specifications

A9N2P50CGN additional specifications
ParameterValue
Depth77.5 mm
Width36 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric A9N2P50CGN is an Acti9 xC60 miniature circuit breaker rated 50 A with a C-curve (magnetic trip 5–10 × In) and two protected poles. It clips onto a 35 mm DIN rail, occupies 36 mm width (4 × 9 mm pitches), and breaks up to 10 kA Icn at 240 V AC or 415 V AC per IS/IEC 60898-1.

The 50 A rated current (In) and C-curve suit general-purpose branch circuits with moderate inrush — think lighting banks, socket outlets, or small motor loads. The thermal-magnetic trip unit handles overloads thermally and short-circuits magnetically; the C-curve's 5–10× In magnetic threshold avoids nuisance tripping on capacitor or motor start currents while still clearing hard faults fast. Breaking capacity of 10 kA at both 240 V and 415 V AC covers most utility-side fault levels in IEC 60898-1 territories; if your point-of-supply SCCR exceeds 10 kA, you'll need an upstream current-limiting device or a higher-rated breaker. The IP20 finger-safe terminals are fine inside a closed enclosure; for outdoor or washdown installs, the breaker lives behind a higher-rated enclosure door.

The toggle gives local ON/OFF indication, and the contact position indicator confirms the state visually.