Schneider Electric A9N2P50CGN — 2-Pole MCB (DIN Rail)

Schneider Electric A9N2P50CGN Acti9 xC60 MCB, 50 A, C-Curve,

MPNA9N2P50CGN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N2P50CGN, 50 A, C-curve, 2-pole, 10 kA breaking capacity, 36 mm wide, clip-on DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9N2P50CGN — Identification
ParameterValue
Product nameXC60
Product rangeActi9
Series / familyActi9
Device short namexC60
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9N2P50CGN — Electrical
ParameterValue
Rated current [In]50 A
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
A9N2P50CGN — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu)10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz conforming to IS/IEC 60898-1
Energy limitation class3 conforming to IS/IEC 60898-1
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9N2P50CGN — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height85 mm
Depth77.5 mm
Mounting support35 mm DIN rail
Mounting modeClip-on
Terminal connectionsBiconnect (bottom) Tunnel type terminals (bottom) 25 mm² flexible Tunnel type terminals (bottom) 35 mm² rigid
Terminal tightening torque3.5 N.m
Comb busbar / distribution block compatibilityTop: YES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
A9N2P50CGN — Environmental
ParameterValue
Operating temperature range-30...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9N2P50CGN — Approvals
ParameterValue
Standards / complianceIS/IEC 60898-1

Product details

The Schneider Electric A9N2P50CGN is an Acti9 xC60 miniature circuit breaker rated 50 A with a C-curve (magnetic trip 5–10 × In) and two protected poles. It clips onto a 35 mm DIN rail, occupies 36 mm width (4 × 9 mm pitches), and breaks up to 10 kA Icn at 240 V AC or 415 V AC per IS/IEC 60898-1.

The 50 A rated current (In) and C-curve suit general-purpose branch circuits with moderate inrush — think lighting banks, socket outlets, or small motor loads. The thermal-magnetic trip unit handles overloads thermally and short-circuits magnetically; the C-curve's 5–10× In magnetic threshold avoids nuisance tripping on capacitor or motor start currents while still clearing hard faults fast. Breaking capacity of 10 kA at both 240 V and 415 V AC covers most utility-side fault levels in IEC 60898-1 territories; if your point-of-supply SCCR exceeds 10 kA, you'll need an upstream current-limiting device or a higher-rated breaker. The IP20 finger-safe terminals are fine inside a closed enclosure; for outdoor or washdown installs, the breaker lives behind a higher-rated enclosure door.

The toggle gives local ON/OFF indication, and the contact position indicator confirms the state visually.

MPN