Skip to main content
Schneider Electric A9N61699

Schneider SW60-DC A9N61699 Switch Disconnector, 50 A 1000 V

MPN A9N61699
Active

Schneider Electric SW60-DC series, switch disconnector, 2-pole, 50 A rated operational current DC-21A at 1000 V DC, 77.4 mm depth, 72 mm width, 132.7 mm height, white, 35 mm DIN rail mount.

$194.54 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N61699 specifications
ParameterValue
Control typeToggle
Main product or component typeSwitch disconnector
Insulation voltage ui1000 V DC
Current50 A DC-21 A 1000 V DC 40 °C 63 A DC-21 A 1000 V DC 5 °C 61 A DC-21 A 1000 V DC 10 °C 60 A DC-21 A 1000 V DC 15 °C 58 A DC-21 A 1000 V DC 20 °C 56 A DC-21 A 1000 V DC 25 °C 54 A DC-21 A 1000 V DC 30 °C 52 A DC-21 A 1000 V DC 35 °C 48 A DC-21 A 1000 V DC 45 °C 46 A DC-21 A 1000 V DC 50 °C 41 A DC-21 A 1000 V DC 60 °C 35 A DC-21 A 1000 V DC 70 °C
Utilization categoryDC-21 A
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree2
ColorWhite
Depth77.4 mm
Width72 mm
Height132.7 mm
Electrical life cycles3000 cycles
Mechanical life cycles20000 cycles
Operating temperature-25...70 °C

Product details

The rating that matters — 50 A at 1000 V DC

The headline number is 50 A rated operational current in DC-21A utilisation category at 1000 V DC and 40 °C ambient. DC-21A covers resistive and lightly inductive loads — think heater banks, not motor drives — so this switch is sized for the DC bus of a solar combiner box or battery string. The rating derates with temperature: at 70 °C it's still good for 35 A DC-21A, while at 5 °C it handles 63 A. That temperature curve is printed on the datasheet because a hot rooftop inverter cabinet pulls the rating down; spec it for the worst-case ambient, not the nameplate.

Isolation and safety

It's certified as a switch disconnector suitable for isolation per EN/IEC 60947-3, with a rated impulse withstand voltage of 6 kV and pollution degree 2. That means it provides visible air-gap isolation when toggled off — no hidden leakage path. Polarity sensitivity is marked: + and - must be respected on connection, so it's not a general-purpose DC breaker you can wire backwards. The voltage drop across the contacts at 50 A is 251 mV (5.02 mOhm, 12.54 W dissipation), which is low enough to avoid thermal trouble in a well-ventilated enclosure.

That means it's still a standard catalog item from Schneider, not a surplus scavenge. If you're freezing a BOM for a solar installation, this part is a safe line item.

That's typical for a disconnect switch — it's not a daily-operating contactor. Tightening torque on the terminals is 3.5 N.m, which is firm but achievable with a standard screwdriver. The 9 mm pitch across 8 positions gives you clear wiring lanes for the DC cables.

MPN