Schneider Electric A9P44732

Schneider Electric A9P44732 Acti9 iC40N MCB, 32 A, 3P+N, B C

MPN A9P44732
Active

Schneider Electric Acti9 iC40N miniature circuit breaker, 32 A, 3P+N, B curve, 10 kA Icu at 400 V AC, DIN-rail clip-on, white.

$126.95 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9P44732 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage400 V AC 50/60 Hz
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite

All specifications

A9P44732 additional specifications
ParameterValue
Depth74 mm
Width54 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric A9P44732 is an Acti9 iC40N miniature circuit breaker rated 32 A, 3P+N, with a B curve and a breaking capacity of 10 kA Icu at 400 V AC (EN/IEC 60947-2) and 6000 A Icn (EN/IEC 60898-1). It clips onto DIN rail, occupies 6 x 9 mm pitches (54 mm wide), and uses thermal-magnetic trip technology. The magnetic trip threshold is 3–5 x In per EN/IEC 60898-1, with a tighter 4 x In ±20 % per EN/IEC 60947-2 — so on a 32 A circuit, the instantaneous trip fires between roughly 96 A and 160 A, which suits resistive and light inductive loads where you want fast clearing without nuisance trips from inrush.

Dual-rated to EN/IEC 60898-1 (domestic/commercial) and EN/IEC 60947-2 (industrial). The 6000 A Icn is the lower IEC 60898-1 rating for residential panels. Limitation class 3 (EN/IEC 60898-1) means it limits let-through energy enough to protect downstream equipment in most branch circuits.

Clip-on mounting to DIN rail. 54 mm wide (6 modules). Tunnel terminals accept 1–16 mm² rigid or 1–10 mm² flexible; strip 14 mm and torque to 2 N·m. Neutral on the left, which matters if you're replacing an existing breaker in a panel with a fixed busbar arrangement. IP20 finger-safe on the front; IP40 inside a modular enclosure.

MPN
A9P44732