Skip to main content
Schneider Electric A9P52710

Schneider Electric A9P52710 Acti9 iC40 MCB, 10 A C-Curve 3P+

MPN A9P52710
Active

Schneider Electric Acti9 iC40, miniature circuit-breaker, 10 A, C curve, 3P+N, 4.5 kA Icn / 6 kA Icu at 400 V AC, clip-on DIN rail.

$99.52 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9P52710 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage400 V AC 50/60 Hz
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite

All specifications

A9P52710 additional specifications
ParameterValue
Depth74 mm
Width54 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric A9P52710 is an Acti9 iC40 miniature circuit-breaker rated 10 A with a C curve, configured 3P+N. The C curve (magnetic trip 5–10 × In per EN/IEC 60898-1, 8 × In ±20% per EN/IEC 60947-2) suits it for mixed resistive and moderate inductive loads — typical for general lighting and socket circuits in commercial or light industrial panels.

Breaking capacity and dual standard rating

This MCB carries two breaking-capacity ratings at 400 V AC: 4.5 kA Icn under EN/IEC 60898-1 (the domestic/light-commercial standard) and 6 kA Icu under EN/IEC 60947-2 (the industrial standard). The 4.5 kA Icn rating is the service breaking capacity for the 60898-1 duty cycle; the 6 kA Icu is the ultimate breaking capacity under 60947-2, and it also qualifies this breaker for isolation duty (marked 'suitable for isolation' per 60947-2).

The 3P+N unit occupies 6 x 9 mm pitches (54 mm total width).

Dual-certified to EN/IEC 60898-1 and EN/IEC 60947-2. Limitation class 3 per 60898-1, pollution degree 3 per 60947-2. IMQ quality label. The part carries an ON/OFF indication and a trip indicator on the toggle. Earth-leakage protection requires a separate block — not integrated.