Skip to main content
Schneider Electric A9P54306

Schneider Electric A9P54306 Acti9 iC40 MCB, 6 A, C-Curve, 3P

MPN A9P54306
Active

Schneider Electric Acti9 iC40N miniature circuit breaker, A9P54306, 6 A rated current, C-curve, 3-pole, 10 kA breaking capacity at 400 V AC per IEC 60947-2, thermal-magnetic trip, clip-on DIN rail mount.

$116.42 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9P54306 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage400 V AC 50/60 Hz
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite

All specifications

A9P54306 additional specifications
ParameterValue
Depth74 mm
Width54 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

Acti9 iC40N — 6 A, C-curve, 3-pole miniature circuit breaker

It's a 3-pole unit rated at 6 A with a C-curve trip characteristic, meaning magnetic tripping occurs between 5 and 10 times the rated current per EN/IEC 60898-1, and at 8 x In ±20% per EN/IEC 60947-2. Breaking capacity is 10 kA Icu at 400 V AC per IEC 60947-2, with an Icn of 6000 A at 400 V per IEC 60898-1. That dual rating gives you selectivity headroom in a typical distribution board — the 10 kA ultimate rating governs fault clearing upstream; the 6 kA service rating covers the downstream branch. The thermal-magnetic trip unit covers sustained overloads and short circuits.

Width is 54 mm (6 x 9 mm pitches), height 85 mm, depth 74 mm. That footprint is common across the Acti9 range — if you're swapping an existing iC40 or iC60 unit, the busbar alignment and enclosure cutout should match. The IP20 terminal protection (IP40 on the modular enclosure per IEC 60529) meets typical panel requirements — not rated for washdown, but fine inside a closed cabinet. Operating altitude is rated to 2000 m without derating.

The breaker carries quality labels from OVE and AENOR, and is certified to the harmonized standards EN/IEC 60898-1 and EN/IEC 60947-2. Compliance documentation (declaration of conformity) is available from the manufacturer for your QA file. This is a standard distribution product — not a safety-rated device with a TÜV SIL certificate, but the isolation suitability and dual-standard breaking capacity give you the typical documentation for an IEC panel.

MPN