Schneider Electric A9P55616

Schneider Electric A9P55616 Acti9 iC40H MCB, 16 A, 10 kA, 1P

MPN A9P55616
Active

Schneider Electric Acti9 iC40H miniature circuit-breaker, A9P55616, 16 A, 10 kA Icn, 1P+N, C-curve, thermal-magnetic trip, clip-on DIN rail mount.

$21.87 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9P55616 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz
Breaking capacity10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9P55616 additional specifications
ParameterValue
ColorWhite
Depth74 mm
Width18 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric A9P55616 is a miniature circuit-breaker from the Acti9 iC40H range. It's rated for a breaking capacity of 10,000 A Icn at 230 V AC, 50/60 Hz, conforming to EN/IEC 60898-1. The limitation class is 3 per the same standard, which means it lets through less fault energy than a Class 1 or 2 breaker, so downstream equipment sees a milder stress during a short. The device is a single module wide (18 mm per pole, so 2 modules for the 1P+N), clips onto a DIN rail, and has tunnel-type terminals that accept up to 16 mm² rigid or 10 mm² flexible copper. The IP20 body is fine for a dry indoor panel; the IP40 modular enclosure rating means it's a bit more protected once installed inside a distribution board.

The C-curve (5-10 x In) is the default for most general-purpose circuits — lighting, receptacles, small motors, control transformers. If your load has a high inrush (like a large motor or a bank of fluorescent ballasts), you'd want a D-curve; if it's purely resistive, a B-curve might do. But for a standard 16 A lighting or general-purpose branch, this is the right curve. The 1P+N configuration means it switches the phase and provides switched neutral isolation, but the neutral pole is not protected — only the phase pole has the thermal-magnetic trip. That's typical for single-phase final circuits in many European distribution boards. The neutral position is left, so it's keyed for the busbar arrangement in Acti9 boards. The electrical and mechanical durability are both rated at 20,000 cycles. That's the standard endurance for a domestic MCB — it'll handle years of normal switching and occasional fault interruptions without wearing out the mechanism. The contact position indicator and the ON/OFF and trip indicator give you a visual check without needing to open the panel door.

It carries a VDE quality label, which is the German safety mark and is widely recognized across Europe. The pollution degree is 3, meaning it's suitable for environments with conductive or dry non-conductive pollution — typical for an indoor distribution board that isn't sealed. The operating altitude is rated to 2,000 m without derating.

MPN
A9P55616