Schneider Electric A9P64725

Schneider Electric A9P64725 Acti9 iC40N MCB, D Curve, 25 A,

MPN A9P64725
Active

Schneider Electric Acti9 iC40N miniature circuit-breaker, A9P64725, 25 A, D curve, 10 kA Icu at 400 V AC, 3P+N, DIN rail clip-on.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9P64725 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage400 V AC 50/60 Hz
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity10 kA Icu at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2

All specifications

A9P64725 additional specifications
ParameterValue
ColorWhite
Depth74 mm
Width54 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric A9P64725 is a 25 A, D-curve miniature circuit-breaker from the Acti9 iC40N series, built for distribution panels where high inrush loads—motor circuits, transformers, or lighting banks—need a magnetic trip that holds past the start surge. The D curve trips at 10–14 × In (per EN/IEC 60898-1) and 12 × In ±20 % (per EN/IEC 60947-2), so it rides through the starting current of a motor or the magnetizing pulse of a transformer without nuisance tripping on the thermal-magnetic element.

Rated breaking capacity is 10 kA Icu at 400 V AC per EN/IEC 60947-2 and 6 kA Icn at 400 V AC per EN/IEC 60898-1. That dual rating matters: the 10 kA figure governs the MCB's ability to interrupt a fault and still be usable after clearing it (the Icu rating), while the 6 kA Icn is the service breaking capacity under the domestic-standard 60898-1. For an industrial panel fed by a transformer with a prospective fault current under 10 kA, this breaker clears it without cascading upstream.

Clip-on mount to DIN rail, 3P+N configuration with neutral on the left. Takes 9 mm pitches for 6 modules. Terminals are tunnel type: 1–16 mm² rigid or 1–10 mm² flexible, torque to 2 N·m. IP20 on the terminals, IP40 on the modular enclosure — fine for a clean indoor panel, but if this is going near crusher vibration or abrasive dust, the enclosure around it needs to seal; the breaker itself shrugs off the mechanical durability at 20,000 cycles and electrical durability at 10,000 cycles.

MPN
A9P64725