Skip to main content
Schneider Electric A9R44492

Schneider Electric A9R44492 Acti9 RCCB-ID, 125 A 4P Type B 3

MPN A9R44492
Active

Schneider Electric Acti9 RCCB-ID, residual current circuit breaker, 4P, 125 A, 300 mA, Type B, 400 V AC, 50 Hz, IEC/EN 61008-1.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9R44492 specifications
ParameterValue
Control typeToggle
Voltage400 V AC 50 Hz conforming to IEC/EN 61008-1 400 V AC 50 Hz conforming to IEC/EN 61008-2-1
Insulation voltage ui400 V AC 50 Hz conforming to IEC/EN 61008-1 400 V AC 50 Hz conforming to IEC/EN 61008-2-1
Terminal pitch18 mm between phases
Temp storage max60 °C
Temp storage min-40 °C
Temp operating max40 °C
Temp operating min-25 °C
Storage temperature-40...60 °C
Pollution degree3
ColorGrey
Depth76 mm
Width72 mm
Height86 mm
Electrical life cycles2000 cycles
Mechanical life cycles5000 cycles
Operating temperature-25...40 °C

Product details

125 A Type B RCCB for 4-wire outgoing circuits

The Schneider Electric A9R44492 is an Acti9 RCCB-ID residual current circuit breaker rated 125 A in a 4-pole (4P) configuration with 300 mA earth-leakage sensitivity and Type B protection class. Type B means it detects AC, pulsating DC, and smooth DC fault currents up to 1 kHz — essential for variable-speed drives, UPS systems, and PV inverters that can inject DC components into the earth path. The 125 A rating and 400 V AC operational voltage suit it for main incoming or large submain protection in three-phase panels. Rated breaking and making capacity is 1250 A at 400 V (IEC/EN 61008-1), which covers the prospective fault current typical of a 125 A outgoing circuit in a commercial or light-industrial distribution board. The instantaneous trip characteristic means no intentional delay — it clears earth faults within the standard response time.

The 76 mm depth and 86 mm height are standard for the Acti9 modular range, so it fits existing distribution boards without re-spacing. Tunnel-type terminals accept up to 50 mm² rigid or 35 mm² flexible cable — enough for 125 A incoming tails. Tightening torque is 3 N.m; wire strip length 11 mm. IP20 finger protection on the terminals, IP40 for the modular enclosure. Padlockable toggle for lockout/tagout. The red/green trip indicator gives a clear visual on the residual current device status without opening the panel door.

The A9R44492 is listed at a current lifecycle stage with no announced end-of-life or last-time-buy. It remains an active catalog item in the Acti9 range.

Standards compliance and approvals

Designed and tested to IEC/EN 61008-1, IEC/EN 61008-2-1, and IEC/EN 62423. Carries VDE quality label. Pollution degree 3 (industrial environment). The 8/20 µs impulse withstand rating of 3 kA means it survives surge events common in mains-fed panels without nuisance tripping.

MPN
A9R44492