Schneider Electric A9R44492 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9R44492 Acti9 RCCB-ID, 125 A 4P Type B 3

MPNA9R44492
Active

Schneider Electric Acti9 RCCB-ID, residual current circuit breaker, 4P, 125 A, 300 mA, Type B, 400 V AC, 50 Hz, IEC/EN 61008-1.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9R44492 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType B
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Local signalling / indicationRed/green indicator Trip indicator
A9R44492 — Electrical Ratings
ParameterValue
Rated current (In)125 A
Rated operational voltage (Ue)400 V AC 50 Hz conforming to IEC/EN 61008-1 400 V AC 50 Hz conforming to IEC/EN 61008-2-1
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50 Hz conforming to IEC/EN 61008-1 400 V AC 50 Hz conforming to IEC/EN 61008-2-1
Rated impulse withstand voltage (Uimp)4 kV conforming to IEC/EN 61008-1 4 kV conforming to IEC/EN 61008-2-1
Device location in systemOutgoer
Electrical durability2000 cycles
Mechanical durability (operating cycles)5000 cycles
A9R44492 — Identification
ParameterValue
Product nameActi9 RCCB-ID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameRCCB-ID
A9R44492 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Control typeToggle
Width in 9 mm modules8
Terminal connectionsTunnel type terminals2 cable(s) 1.5...16 mm² flexible Tunnel type terminals2 cable(s) 1.5...16 mm² rigid Tunnel type terminals1 cable(s) 1.5...50 mm² rigid Tunnel type terminals1 cable(s) 1.5...35 mm² flexible Tunnel type terminals1 cable(s) 1.5...35 mm² flexible with ferrule Tunnel type terminals2 cable(s) 1.5...16 mm² flexible with ferrule
Wire stripping length11 mm
Terminal tightening torque3 N.m
Width72 mm
Height86 mm
Depth76 mm
A9R44492 — Environmental
ParameterValue
Operating ambient temperature-25...40 °C
Storage ambient temperature-40...60 °C
IP degree of protectionIP20 conforming to IEC/EN 60529 IP20 conforming to IEC/EN 62423 IP40 (modular enclosure) conforming to IEC/EN 60529 IP40 (modular enclosure) conforming to IEC/EN 62423
Pollution degree3
A9R44492 — Approvals
ParameterValue
StandardsIEC/EN 61008-1 IEC/EN 61008-2-1 IEC/EN 62423

Product details

125 A Type B RCCB for 4-wire outgoing circuits

The Schneider Electric A9R44492 is an Acti9 RCCB-ID residual current circuit breaker rated 125 A in a 4-pole (4P) configuration with 300 mA earth-leakage sensitivity and Type B protection class. Type B means it detects AC, pulsating DC, and smooth DC fault currents up to 1 kHz — essential for variable-speed drives, UPS systems, and PV inverters that can inject DC components into the earth path. The 125 A rating and 400 V AC operational voltage suit it for main incoming or large submain protection in three-phase panels. Rated breaking and making capacity is 1250 A at 400 V (IEC/EN 61008-1), which covers the prospective fault current typical of a 125 A outgoing circuit in a commercial or light-industrial distribution board. The instantaneous trip characteristic means no intentional delay — it clears earth faults within the standard response time.

The 76 mm depth and 86 mm height are standard for the Acti9 modular range, so it fits existing distribution boards without re-spacing. Tunnel-type terminals accept up to 50 mm² rigid or 35 mm² flexible cable — enough for 125 A incoming tails. Tightening torque is 3 N.m; wire strip length 11 mm. IP20 finger protection on the terminals, IP40 for the modular enclosure. Padlockable toggle for lockout/tagout. The red/green trip indicator gives a clear visual on the residual current device status without opening the panel door.

The A9R44492 is listed at a current lifecycle stage with no announced end-of-life or last-time-buy. It remains an active catalog item in the Acti9 range.

Standards compliance and approvals

Designed and tested to IEC/EN 61008-1, IEC/EN 61008-2-1, and IEC/EN 62423. Carries VDE quality label. Pollution degree 3 (industrial environment). The 8/20 µs impulse withstand rating of 3 kA means it survives surge events common in mains-fed panels without nuisance tripping.

Frequently asked questions

What is the A9R44492 used for?

It is a 4-pole 125 A Type B residual current circuit breaker (RCCB) for earth-leakage protection on three-phase outgoing circuits. Type B detection covers AC, pulsating DC, and smooth DC fault currents, making it suitable for circuits with variable-speed drives, UPS, or photovoltaic inverters.

What is the closest alternative to the A9R44492?

Within the Acti9 range, the closest functional sibling is the A9R44491 (same 4P Type B 300 mA but rated 100 A instead of 125 A). The A9R44492 is the higher-current variant for 125 A circuits. No pin-compatible drop-in exists at a different current rating — the terminal size and pitch are identical, but the thermal rating differs.

How do I get pricing and availability for the A9R44492?

Submit an RFQ through this listing. The part is sourced to order via independent distribution; current pricing and lead time are confirmed at quote time.

What compliance documentation does Schneider provide for the A9R44492?

The A9R44492 is certified to IEC/EN 61008-1, IEC/EN 61008-2-1, and IEC/EN 62423, with a VDE quality label. Standard Schneider documentation includes a declaration of conformity covering the applicable EU directives (LV Directive, EMC Directive). RoHS and REACH compliance data is available on request.

MPN
A9R44492