Skip to main content
Schneider Electric A9TDF3606

Schneider Electric A9TDF3606 Acti9 iCV40 ARC RCBO, 6A C-curv

MPN A9TDF3606
Active

Schneider Electric Acti9 iCV40 ARC, RCBO, 1P+N, 6 A, C-curve, 6 kA Icn, arc fault detection, DIN rail mount, white (RAL 9003).

$323.68 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9TDF3606 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeArc fault detection RCBO
Voltage230 V AC 50 Hz
Insulation voltage ui250 V AC 50 Hz between phase and neutral
Breaking capacity6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 61009-2-1 10 kA Icu at 230 V AC 50 Hz conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max50 °C
Temp operating min-25 °C
Storage temperature-40...80 °C

All specifications

A9TDF3606 additional specifications
ParameterValue
Pollution degree2 conforming to EN/IEC 62606
ColorWhite (RAL 9003)
Depth73 mm
Width36 mm
Height91 mm
Electrical life cycles20000 cycles 230 V AC 50 Hz
Mechanical life cycles20000 cycles
Operating temperature-25...50 °C

Product details

The 6 kA Icn breaking capacity at 230 V AC (EN/IEC 61009-2-1) is the standard domestic and light-commercial fault level; the 10 kA Icu rating (EN/IEC 60947-2) gives headroom for industrial panel coordination studies. This is a 1P+N device — single-pole switched, neutral solid — so it fits single-phase final subcircuits where arc-fault detection is required by code (e.g. EN 62606).

Arc fault detection — what it adds

The 'ARC' suffix means this RCBO includes series and parallel arc-fault detection per EN/IEC 62606. It looks for the high-frequency signature of a loose connection or damaged cable insulation — the kind of fault a standard MCB or RCD won't catch until it becomes a fire. The local signalling includes a dedicated fault-trip LED for arc fault diagnostic, so when it trips you know whether it was an overload, a residual current, or an arc event. That saves chasing ghost trips on a line.

Tunnel terminals accept 1...16 mm² rigid or 1...10 mm² flexible; wire stripping length 14 mm, tightening torque 2 N.m. Cable entry top and bottom, neutral on the left. IP20 finger-safe terminals. The tropicalisation rating (severity B per IEC 60068-2-30, 28 days) means it handles high-humidity environments — 95 % RH at 55 °C — without internal condensation tracking.

MPN