Schneider Electric A9TDF3610

A9TDF3610 Acti9 iCV40N ARC 10A C-Curve AFDD+MCB, 6kA

MPN A9TDF3610
Active

Schneider Electric Acti9 iCV40N ARC, 1P+N, 10 A, C-curve, 6 kA Icn / 10 kA Icu, arc fault detection device (AFDD) + MCB combination, DIN-rail mount.

$323.68 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9TDF3610 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeArc fault detection RCBO
Voltage230 V AC 50 Hz
Insulation voltage ui250 V AC 50 Hz between phase and neutral
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max50 °C
Temp operating min-25 °C
Storage temperature-40...80 °C
Pollution degree2 conforming to EN/IEC 62606

All specifications

A9TDF3610 additional specifications
ParameterValue
ColorWhite (RAL 9003)
Depth73 mm
Width36 mm
Height91 mm
Electrical life cycles20000 cycles 230 V AC 50 Hz
Mechanical life cycles20000 cycles
Operating temperature-25...50 °C

Product details

Arc-fault + overcurrent in one 36 mm module

The A9TDF3610 is a Schneider Electric Acti9 iCV40N ARC — a combined arc-fault detection device (AFDD) and miniature circuit breaker in a single 1P+N, 36 mm wide DIN-rail module. It carries a 10 A rated current with a C-curve magnetic trip (5–10 x In) and a 6 kA Icn / 10 kA Icu breaking capacity at 230 V AC, 50 Hz, per EN/IEC 61009-2-1 and EN/IEC 60947-2. The arc-fault detection is the primary differentiator here: it monitors for the high-frequency signature of a series or parallel arc (e.g., a loose terminal, a crushed cable) and trips before the arc has time to propagate into a panel fire. The diagnostic LED on the toggle gives a local indication of an arc-fault trip versus an overload or short — saves the commissioning engineer a clamp-meter hunt on a nuisance-trip callout.

What the 6 kA Icn / 10 kA Icu means for your panel

The 6 kA Icn (rated short-circuit capacity per EN/IEC 61009-2-1) is the breaker's tested interrupting rating under the MCB standard — it clears a 6 kA fault at 230 V and remains serviceable afterward. The 10 kA Icu (ultimate breaking capacity per EN/IEC 60947-2) is the higher one-shot rating under the industrial standard; the breaker will interrupt a 10 kA fault but may need replacement afterward. For most commercial and light-industrial distribution boards with a prospective fault current under 6 kA, the Icn figure governs the daily duty. The 10 kA Icu gives headroom for a stronger upstream transformer or a closer fault location without cascading. The C-curve (5–10 x In) means the magnetic trip fires between 50 A and 100 A — suitable for general-purpose loads with moderate inrush, like lighting banks, small motor circuits, or socket outlets. The thermal-magnetic trip mechanism is a traditional bimetal + solenoid, field-reliable and predictable.

Cable entry from top or bottom — no forced feed direction, which helps with busbar or loop-through wiring in a crowded enclosure. Pollution degree 2 (non-conductive dust, occasional condensation) per EN/IEC 62606.