Skip to main content
Schneider Electric A9TDF3616

A9TDF3616 Acti9 iCV40 ARC 1P+N 16A C-curve RCBO, 6kA/10kA

MPN A9TDF3616
Active

Schneider Electric Acti9 iCV40 ARC RCBO, 1P+N, 16 A, C-curve, 6 kA Icn / 10 kA Icu at 230 V AC, DIN-rail clip-on, white (RAL 9003).

$323.68 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9TDF3616 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeArc fault detection RCBO
Voltage230 V AC 50 Hz
Insulation voltage ui250 V AC 50 Hz between phase and neutral
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max50 °C
Temp operating min-25 °C
Storage temperature-40...80 °C
Pollution degree2 conforming to EN/IEC 62606

All specifications

A9TDF3616 additional specifications
ParameterValue
ColorWhite (RAL 9003)
Depth73 mm
Width36 mm
Height91 mm
Electrical life cycles20000 cycles 230 V AC 50 Hz
Mechanical life cycles20000 cycles
Operating temperature-25...50 °C

Product details

The Schneider Electric A9TDF3616 is an Acti9 iCV40 ARC residual current circuit breaker with overcurrent protection (RCBO), 1P+N, rated 16 A with a C-curve magnetic trip characteristic (5...10 x In). It breaks 6 kA Icn per EN/IEC 61009-2-1 and 10 kA Icu per EN/IEC 60947-2 at 230 V AC, 50 Hz — enough for most residential and light commercial final circuits where fault levels stay under 10 kA. The thermal-magnetic trip unit handles overload and short-circuit; the integrated residual current element adds earth-leakage protection in one 36 mm wide DIN-rail module.

The 16 A rated current and C-curve (5–10 x In magnetic trip) suit general-purpose socket circuits, lighting, and small appliance loads where inrush is moderate — think office power outlets or domestic ring mains. The 6 kA Icn is the service breaking capacity for routine faults; the 10 kA Icu is the ultimate breaking capacity for rare high-fault events, giving the installer headroom in selectivity coordination with an upstream 10 kA-rated MCB or fuse. IP20 rated — suitable for enclosed distribution boards only. The toggle control with ON/OFF/fault-trip LED and arc-fault diagnostic signalling gives a quick visual on the circuit state.

MPN