Skip to main content
Schneider Electric A9TDFC606

Schneider Electric A9TDFC606 Acti9 Active iCV40 ARC, 6 A, Cu

MPN A9TDFC606
Active

Schneider Electric Acti9 Active iCV40 ARC arc-fault detection device, 1P+N, 6 A rated current, curve C, 6 kA Icn / 10 kA Icu, clip-on DIN rail, white (RAL 9003).

$356.51 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9TDFC606 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230 V AC 50 Hz
Insulation voltage ui250 V AC 50 Hz between phase and neutral
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max50 °C
Temp operating min-25 °C
Storage temperature-40...80 °C
Pollution degree2 conforming to EN/IEC 62606
ColorWhite (RAL 9003)

All specifications

A9TDFC606 additional specifications
ParameterValue
Depth73 mm
Width36 mm
Height91 mm
Electrical life cycles20000 cycles 230 V AC 50 Hz
Mechanical life cycles20000 cycles
AccuracyVoltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %
Operating temperature-25...50 °C

Product details

The 6 kA Icn is the service breaking capacity per EN/IEC 61009-2-1; the 10 kA Icu per EN/IEC 60947-2 is the ultimate breaking capacity, giving headroom for fault currents up to 10 kA at 230 V AC. The thermal-magnetic trip unit handles overloads via a bimetal strip and short-circuits via a solenoid — no electronics to fail in the trip path. The arc-fault detection adds series arc monitoring per EN/IEC 62606, which means it can distinguish a dangerous arc (loose connection, damaged cable) from normal switching arcs. That's the main value over a standard RCBO: it catches faults a thermal-magnetic alone misses. Accuracy for the measurement functions is ±2 % for voltage and current, ±5 % for power — good enough for energy monitoring and fault logging, not for revenue-grade metering. The local signalling includes an LED for arc-fault diagnostics, so a maintenance tech can tell at a glance whether the trip was from an arc event or a conventional overload/earth leakage.

Deployment context

Cable entry from top and bottom gives flexibility in busbar or wired layouts. The tropicalisation rating — severity B per IEC 60068-2-30 for 28 days — means it handles high-humidity storage and operation, which matters for sites in coastal or tropical climates.

MPN
A9TDFC606