Schneider Electric A9TDFC610

Schneider Electric A9TDFC610 Acti9 iCV40 ARC RCBO, 10 A, C C

MPN A9TDFC610
Active

Schneider Electric Acti9 range, iCV40N ARC RCBO, 1P+N, 10 A, C curve, 6 kA Icn, arc-fault detection, clip-on DIN rail mount.

$356.51 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9TDFC610 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230 V AC 50 Hz
Insulation voltage ui250 V AC 50 Hz between phase and neutral
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max50 °C
Temp operating min-25 °C
Storage temperature-40...80 °C
Pollution degree2 conforming to EN/IEC 62606
ColorWhite (RAL 9003)

All specifications

A9TDFC610 additional specifications
ParameterValue
Depth73 mm
Width36 mm
Height91 mm
Electrical life cycles20000 cycles 230 V AC 50 Hz
Mechanical life cycles20000 cycles
AccuracyVoltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %
Operating temperature-25...50 °C

Product details

It packs three protection functions into one DIN-rail unit: arc-fault detection per EN/IEC 62606, earth-leakage protection, and thermal-magnetic overcurrent protection (C curve, 10 A rated). For the panel builder, that means one clip-on device covers arc-fault, ground-fault, and branch-circuit overcurrent — no separate AFCI module needed, saving two DIN spaces. Breaking capacity: 6 kA Icn at 230 V AC per EN/IEC 61009-2-1 (the RCBO standard), and 10 kA Icu per EN/IEC 60947-2 (the MCCB standard). Measurement accuracy: ±2 % on voltage and current, ±5 % on active power and power factor. That's metering-grade — good enough for energy monitoring and load profiling on a branch circuit, not utility-billing accuracy. The device reports these values locally via the arc-fault diagnostic LED and toggle position, not over a bus.

Clip-on DIN rail mount, 36 mm wide (4 x 9 mm pitches), 73 mm deep. That 73 mm depth is tight in shallow enclosures — check your gland-plate clearance if the panel is under 80 mm useable depth. Rated for pollution degree 2, overvoltage category III, and tropicalisation severity B per IEC 60068-2-30 (28-day damp-heat cycle). That means it's fine in unconditioned enclosures, humid basements, or outdoors under a weatherproof housing — the 95 % RH at 55 °C limit covers most European and coastal installations.

Approvals and compliance paperwork

Carries IMQ, AENOR, and OVE quality labels — those are Italian, Spanish, and Austrian national marks, respectively. Standards compliance: EN/IEC 62606 (arc-fault detection), EN/IEC 61009-1 and -2-1 (RCBO), and EN/IEC 60947-2 (MCCB supplementary). For the quality-doc controller, that covers the European Low Voltage Directive via CE marking; no separate UL or CSA listing is on the record.

MPN