Skip to main content
Schneider Electric A9TDFC625

Schneider Electric A9TDFC625 Acti9 iCV40 ARC RCBO, 25 A, 6 k

MPN A9TDFC625
Active

Schneider Electric Acti9 Active iCV40 ARC, order code A9TDFC625, 1P+N RCBO, 25 A rated, Type C curve, 6 kA Icn breaking capacity, arc fault detection.

$359.91 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9TDFC625 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230 V AC 50 Hz
Insulation voltage ui250 V AC 50 Hz between phase and neutral
Breaking capacity6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 61009-2-1 10 kA Icu at 230 V AC 50 Hz conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max50 °C
Temp operating min-25 °C
Storage temperature-40...80 °C
Pollution degree2 conforming to EN/IEC 62606

All specifications

A9TDFC625 additional specifications
ParameterValue
ColorWhite (RAL 9003)
Depth73 mm
Width36 mm
Height91 mm
Electrical life cycles20000 cycles 230 V AC 50 Hz
Mechanical life cycles20000 cycles
AccuracyVoltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %
Operating temperature-25...50 °C

Product details

The Schneider Electric A9TDFC625 is an Acti9 Active iCV40 ARC residual current circuit breaker with overcurrent protection (RCBO) and integrated arc fault detection. It is a 1P+N device rated at 25 A with a Type C tripping curve, designed for final-circuit protection in AC networks at 50 Hz. The breaking capacity is 6000 A Icn per EN/IEC 61009-2-1 and 10 kA Icu per EN/IEC 60947-2, which means it can safely interrupt fault currents up to those levels without upstream cascading — a key selectivity consideration for panel coordination.

Arc fault detection and measurement

The A9TDFC625 includes arc fault detection (the "ARC" in the name) as an integrated function, distinguishing it from a standard RCBO. It measures voltage, active power, current, and power factor with accuracy of ±2 % for voltage and current, and ±5 % for power. The local signalling includes a fault-trip LED for arc fault diagnostics, which supports troubleshooting without additional equipment.

The unit clips onto a DIN rail (35 mm) and occupies 36 mm width (4 x 9 mm pitches). For panel builders: the 73 mm depth fits standard distribution boards, and the white RAL 9003 finish matches the Acti9 family aesthetic.

MPN
A9TDFC625