A9TPDD610 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230 V AC 50 Hz
Insulation voltage ui250 V AC
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max40 °C
Temp operating min-25 °C
Storage temperature-40...80 °C
Pollution degree2
ColorWhite (RAL 9003)

All specifications

A9TPDD610 additional specifications
ParameterValue
Depth73 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
AccuracyVoltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %
Operating temperature-25...40 °C

Product details

It complies with EN/IEC 60898-1 (MCB standard), EN/IEC 60947-2 (low-voltage switchgear), and EN/IEC 62606 (arc-fault detection), so it meets the requirements for arc-fault protection in many national wiring regulations.

The breaking capacity is 6000 A Icn per EN/IEC 60898-1 at 230 V AC, and 10 kA Icu per EN/IEC 60947-2 — enough for most residential and light-commercial service-entrance fault levels. The 3000 A Icn1 rating (60898-1) covers the lower end of the standard's test sequence. Clip-on mounting to a 35 mm DIN rail (EN 60715) and a width of 36 mm (4 x 9 mm pitches) mean it occupies a single module space in a consumer unit or distribution board. The IP20 finger-safe terminals are standard for enclosed panels. Local signalling includes ON/OFF position and a fault-trip LED with arc-fault diagnostics.

Installation notes

Tunnel-type terminals accept 1–10 mm² flexible or 1–16 mm² rigid copper. Cable entry from top or bottom, neutral on the left. Rated for 2000 m operating altitude, pollution degree 2, and tropicalisation severity B (28-day damp-heat cycle per IEC 60068-2-30). Electrical durability is 10 000 cycles, mechanical durability 20 000 cycles.