A9TPED616 Acti9 iC40N ARC 16A 1P+N MCB, Curve C, 6kA

MPN A9TPED616
Active

Schneider Electric Acti9 Active ARC iC40N, A9TPED616, 1P+N MCB with arc-fault detection, 16 A, curve C, 6 kA Icn, 10 kA Icu, 3 kA Icn1, white (RAL 9003).

$353.05 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9TPED616 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230 V AC 50 Hz
Insulation voltage ui250 V AC
Breaking capacity3000 A Icn1 at 230 V AC 50 Hz conforming to EN/IEC 60898-1 10 kA Icu at 230 V AC 50 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max40 °C
Temp operating min-25 °C
Storage temperature-40...80 °C
Pollution degree2

All specifications

A9TPED616 additional specifications
ParameterValue
ColorWhite (RAL 9003)
Depth73 mm
Width36 mm
Height91 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
AccuracyVoltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %
Operating temperature-25...40 °C

Product details

The A9TPED616 is a 1P+N arc-fault detection MCB from the Acti9 Active ARC iC40N series, rated 16 A with a C trip curve. It combines overcurrent protection (thermal-magnetic) with arc-fault detection for series and parallel arcs, covering the outgoer position in a final distribution board. The 6 kA Icn at 230 V AC (EN/IEC 60898-1) and 10 kA Icu (EN/IEC 60947-2) give it the interrupting capacity for residential and light commercial panels where the prospective fault current stays under those thresholds. The 3 kA Icn1 rating is the lower limit for the IEC 60898-1 domestic standard — the 6 kA figure is the one you size the board's upstream device against.

Arc-fault detection and selectivity

This is not a plain MCB. The Active ARC logic monitors the waveform for the high-frequency signature of an arc fault — series (loose connection) and parallel (tracking) — and trips the breaker when it exceeds the detection threshold. The magnetic trip limit is 5 to 10 × In, so for a 16 A unit the instantaneous magnetic pickup sits between 80 A and 160 A. That range is standard for curve C and means the breaker will hold motor inrush on small pumps or compressors but still clear a hard short. The limitation class 3 rating tells you the let-through energy is low enough to protect downstream cables without an upstream current-limiting fuse in most domestic configurations.

Clip-on mounting onto a DIN rail, 36 mm wide (2 x 9 mm pitches), 73 mm deep, 91 mm tall. The IP20 finger-safe rating is fine for enclosed distribution boards — no special gasketing needed.