Skip to main content
Schneider Electric A9TPED640

Schneider A9TPED640 Acti9 iC40N ARC MCB, 40 A, 1P+N, C-curve

MPN A9TPED640
Active

Schneider Electric Acti9 Active ARC iC40N, A9TPED640, 1P+N miniature circuit breaker, 40 A rated, C-curve, 10 kA Icu at 230 V AC, DIN-rail mount, IP20.

$353.05 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9TPED640 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230 V AC 50 Hz
Insulation voltage ui250 V AC
Breaking capacity3000 A Icn1 at 230 V AC 50 Hz conforming to EN/IEC 60898-1 10 kA Icu at 230 V AC 50 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max40 °C
Temp operating min-25 °C
Storage temperature-40...80 °C
Pollution degree2

All specifications

A9TPED640 additional specifications
ParameterValue
ColorWhite (RAL 9003)
Depth73 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
AccuracyVoltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %
Operating temperature-25...40 °C

Product details

The Schneider Electric A9TPED640 is an Acti9 Active ARC iC40N miniature circuit breaker (MCB) — a single-pole-plus-neutral device rated 40 A with a C-curve trip characteristic, built for AC networks at 50 Hz. It sits on a DIN rail in the outgoing feeder position of a distribution board, protecting branch circuits against overload and short-circuit faults.

Breaking capacity — what the three numbers mean

This breaker carries three breaking-capacity ratings, each tied to a different standard. At 230 V AC, 50 Hz: 3000 A Icn per EN/IEC 60898-1 (the domestic/commercial MCB standard), 6000 A Icn per the same standard, and 10 kA Icu per EN/IEC 60947-2 (the industrial standard for switchgear). The lower Icn values reflect the less demanding test sequence of the MCB standard. For a cement plant or similar dusty environment, the 10 kA SCCR headroom means this part coordinates cleanly with a downstream 40 A load and an upstream feeder breaker sized for the panel's available fault current.

Width is 36 mm, height 91 mm, depth 73 mm. Clips onto a DIN rail. Neutral on the left, supply cable entry at top or bottom.

Measurement and diagnostics — what the accuracy tells you

The iC40N ARC variant includes embedded measurement of voltage, current, active power, and power factor, with stated accuracy: ±2 % for voltage and current, ±5 % for power.

MPN
A9TPED640