Skip to main content
Schneider Electric A9TSB3625

Schneider Electric A9TSB3625 Acti9 iARC AFDD, 25 A, 1P+N

MPN A9TSB3625
Active

Schneider Electric Acti9 iARC arc fault detection switch (AFDD), A9TSB3625, 25 A rated, 1P+N, 230 V AC, IEC 62606, DIN rail mount.

$256.82 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9TSB3625 specifications
ParameterValue
Control typeToggle
Main product or component typeArc fault detection switch
Voltage230 V AC 50 Hz conforming to IEC 62606
Insulation voltage ui250 V
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max40 °C
Temp operating min-25 °C
Storage temperature-40...80 °C
Pollution degree2 conforming to IEC 62606
ColorWhite (RAL 9003)
Depth73 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles 230 V AC 50 Hz conforming to IEC 62606
Mechanical life cycles20000 cycles
Operating temperature-25...40 °C

Product details

The Schneider Electric A9TSB3625 is an Acti9 iARC arc fault detection switch (AFDD) rated at 25 A, 1P+N, 230 V AC 50 Hz, built to IEC 62606. The 25 A rating means it protects a final subcircuit (outgoer) against series and parallel arcing faults that a standard MCB alone cannot detect.

Rated breaking capacity is 500 A (Im = 500 A, Im1 = 500 A) — that is the maximum fault current the device can safely interrupt at 230 V AC. The threshold tripping voltage is 275 V ±5 V, meaning the AFDD detects arc faults when the voltage across the arc exceeds that window; it is designed for a 230 V AC nominal network. Electrical durability is 10,000 cycles at 230 V AC 50 Hz per IEC 62606; mechanical durability is 20,000 cycles. The lower electrical figure reflects contact wear under load — for a switch that may trip under fault, 10,000 operations is well beyond the service life of a typical residential or light commercial final circuit. The toggle control and local signalling (ON, OFF, fault trip LED) give a clear visual indication of the device state and the reason for a trip. Pollution degree 2 per IEC 62606 means the device is rated for normal indoor environments where only non-conductive pollution occurs (occasional condensation).

Neutral is on the left (1P+N configuration). The device includes a padlocking option for lockout/tagout during maintenance.

MPN
A9TSB3625