Skip to main content
Schneider Electric A9TSB3625 — 1-Pole MCB (DIN Rail)

Schneider Electric A9TSB3625 Acti9 iARC AFDD, 25 A, 1P+N

MPNA9TSB3625
Active

Schneider Electric Acti9 iARC arc fault detection switch (AFDD), A9TSB3625, 25 A rated, 1P+N, 230 V AC, IEC 62606, DIN rail mount.

$256.82Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9TSB3625 — Identification
ParameterValue
Product nameActi9 iARC
Product / component typeArc fault detection switch
Device short nameiARC
Poles description1P + N

Electrical & Protection

A9TSB3625 — Electrical & Protection
ParameterValue
Rated current (In)25 A
Rated operational voltage (Ue)230 V AC 50 Hz conforming to IEC 62606
Network type (AC/DC)AC
Network frequency50 Hz
Overvoltage categoryIII
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles

Mounting & Connection

A9TSB3625 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminal1...16 mm² rigid Tunnel type terminal1...10 mm² flexible
Mounting supportDIN rail
Mounting modeClip-on
Width36 mm
Height91 mm
Depth73 mm
Tightening torque (by circuit)2 N.m

Environmental

A9TSB3625 — Environmental
ParameterValue
Operating ambient temperature-25...40 °C
Storage ambient temperature-40...80 °C

Approvals

A9TSB3625 — Approvals
ParameterValue
Conformity standardsIEC 62606

Electrical

A9TSB3625 — Electrical
ParameterValue
[Ui] rated insulation voltage250 V
[Uimp] rated impulse withstand voltage4 kV conforming to IEC 62606

Product details

The Schneider Electric A9TSB3625 is an Acti9 iARC arc fault detection switch (AFDD) rated at 25 A, 1P+N, 230 V AC 50 Hz, built to IEC 62606. The 25 A rating means it protects a final subcircuit (outgoer) against series and parallel arcing faults that a standard MCB alone cannot detect.

Rated breaking capacity is 500 A (Im = 500 A, Im1 = 500 A) — that is the maximum fault current the device can safely interrupt at 230 V AC. The threshold tripping voltage is 275 V ±5 V, meaning the AFDD detects arc faults when the voltage across the arc exceeds that window; it is designed for a 230 V AC nominal network. Electrical durability is 10,000 cycles at 230 V AC 50 Hz per IEC 62606; mechanical durability is 20,000 cycles. The lower electrical figure reflects contact wear under load — for a switch that may trip under fault, 10,000 operations is well beyond the service life of a typical residential or light commercial final circuit. The toggle control and local signalling (ON, OFF, fault trip LED) give a clear visual indication of the device state and the reason for a trip. Pollution degree 2 per IEC 62606 means the device is rated for normal indoor environments where only non-conductive pollution occurs (occasional condensation).

Neutral is on the left (1P+N configuration). The device includes a padlocking option for lockout/tagout during maintenance.

Frequently asked questions

How do I get current pricing and availability for A9TSB3625?

Submit an RFQ for the A9TSB3625. We source this part to order through independent distribution and confirm current pricing and availability at quote time.

What is A9TSB3625's listed depth (73 mm) on this component line?

The A9TSB3625 has a listed depth of 73 mm, which fits standard distribution board cutouts.

What is A9TSB3625's listed width (36 mm) on this component line?

The A9TSB3625 has a listed width of 36 mm, occupying two standard 18 mm modular pitches on a DIN rail.

MPN
A9TSB3625