Skip to main content
Schneider Electric A9TYA4225

A9TYA4225 Acti9 VigiARC iC60, 25 A, 30 mA, 2P

MPN A9TYA4225
Active

Schneider Electric Acti9 VigiARC iC60, arc fault detection with residual current protection add-on block, A9TYA4225, 25 A, 30 mA, 2P, 230 V AC, DIN rail clip-on.

$329.99 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9TYA4225 specifications
ParameterValue
Voltage230 V AC
Insulation voltage ui400 V AC
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree2
ColorWhite (RAL 9003)
Depth73 mm
Width54 mm
Height91 mm
Electrical life cycles10000 cycles > 25 A 20000 cycles <= 25 A
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

The A9TYA4225 is an Acti9 VigiARC iC60 add-on block that combines arc fault detection with residual current protection in a single 2-pole module. The 25 A rated current and 230 V AC operational voltage suit it for final circuits supplying socket outlets, lighting, or small appliances in residential or light commercial panels where the standard demands AFDD + RCD in one device.

The 30 mA earth-leakage sensitivity is Type A-SI (Super Immunised), meaning it handles pulsed DC fault currents and resists nuisance tripping from high-frequency inverter or LED-driver leakage — a common pain point in modern panels where non-linear loads are present. The arc fault detection follows EN/IEC 62606, so it discriminates between harmless arcs (motor brush noise, switch arcing) and dangerous series/parallel arcs that cause electrical fires. Voltage-independent residual current tripping means the RCD function operates even if the neutral is lost upstream — the trip coil draws its energy from the fault itself, not the supply. Rated insulation voltage is 400 V AC, impulse withstand 4 kV, and pollution degree 2 — standard for a clean indoor distribution board. The 50 Hz network frequency and 2-pole configuration (switched phase + switched neutral, neutral left) match the common single-phase final circuit layout across Europe and many other 50 Hz territories.

IP20 finger-safe terminals are fine for enclosed distribution boards; no washdown rating here.

Field diagnostics and data

Local signalling includes ON/OFF position and a fault-trip LED with arc fault diagnostic — the LED distinguishes between arc fault trips and earth-leakage trips, saving a service call to identify the cause. Electrical data recording logs date, time, and maintenance indicators, which helps track recurring faults on a circuit.

MPN