Skip to main content
Schneider Electric A9TYAE225

Schneider Electric A9TYAE225 Acti9 VigiARC iC60, 25 A 30 mA

MPN A9TYAE225
Active

Schneider Electric Acti9 Active VigiARC iC60, arc-fault detection + residual-current add-on block, 2P, 25 A, 30 mA, 230 V AC, clip-on DIN-rail mount.

$395.87 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9TYAE225 specifications
ParameterValue
Voltage230 V AC
Insulation voltage ui400 V AC
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree2
ColorWhite (RAL 9003)
Depth73 mm
Width54 mm
Height91 mm
Electrical life cycles10000 cycles > 25 A 20000 cycles <= 25 A
Mechanical life cycles20000 cycles
AccuracyVoltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %
Operating temperature-25...60 °C

Product details

The Schneider Electric A9TYAE225 is an Active arc-fault detection device with residual-current protection — a combined AFDD + RCD add-on block from the Acti9 VigiARC iC60 range. Rated at 25 A continuous on a 230 V AC network (50 Hz), with an insulation voltage of 400 V AC. The trip threshold for overvoltage is 275 V ±5 V — meaning it catches sustained swells that could start a fire in loose connections or degraded insulation.

Built to EN/IEC 62606 (arc-fault detection devices), EN/IEC 61009-1 (RCBOs), and EN/IEC 61009-2-1 (functional). Earth-leakage protection is Type A-SI (Super Immunised), which means it resists nuisance tripping from high-frequency harmonics or transient surges common on inverter-fed circuits or long cable runs.

Clip-on mount on standard DIN rail (35 mm), 2-pitch wide (9 mm per pitch). Dimensions: 91 mm high, 54 mm wide, 73 mm deep. Terminals accept 0.2–2.5 mm² solid or stranded wire; strip length 14 mm, tighten to 2 N·m. Pollution degree 2 (normal, non-conductive). Ambient storage range -40 to 85 °C, tropicalised to severity B per IEC 60068-2-30 for 28 days — survives the nacelle or a humid panel room.

Signalling and diagnostics

Local signalling includes ON, OFF, fault-trip LED, and an arc-fault diagnostic indicator. Records date/time of events and maintenance indicators — compatible with EcoStruxure Panel Server (Entry, Advanced, Universal) for remote monitoring. Accuracy for voltage, current, and power is ±2 %; power factor measurement is ±5 %. Electrical durability: 20,000 cycles at ≤25 A, 10,000 cycles above. Mechanical durability: 20,000 cycles.

MPN