Schneider Electric A9V61363

Schneider Electric A9V61363 Acti9 Vigi iC60, 3P, 63A, 30mA,

MPN A9V61363
Active

Schneider Electric Acti9 Vigi iC60 add-on residual current device, A9V61363, 3P, 63 A, 30 mA Type A-SI, instantaneous, 400-415 V AC, DIN rail clip-on.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9V61363 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage400...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 400...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-2
Depth73.5 mm
Width117 mm
Height91 mm
Operating temperature-25...60 °C

Product details

The Schneider Electric A9V61363 is an add-on residual current device (RCD) from the Acti9 Vigi iC60 range, designed to clip onto the side of an iC60 MCB to add earth-leakage protection to that circuit. It is a voltage-independent, instantaneous-trip unit rated at 63 A with a 30 mA sensitivity, Type A-SI (Super Immunised) — meaning it handles pulsed DC fault currents and resists nuisance tripping from high-frequency harmonics common on modern electronic loads. The 3-pole version operates at 400-415 V AC, 50/60 Hz, and mounts on a standard DIN rail via the clip-on mechanism, occupying 7 x 9 mm pitches (117 mm width).

The 63 A rated current (In) sets the maximum continuous load this RCD can carry — sized for a 63 A feeder, not the load side of a smaller MCB. The 30 mA sensitivity is the standard threshold for personnel protection (shock risk) per IEC 60364. Type A-SI (Super Immunised) means it is tested to withstand 8/20 µs impulse currents up to 3000 A without tripping, so it stays stable on circuits with surge suppressors or variable-speed drives upstream. The instantaneous trip (no intentional delay) makes it suitable for direct fault clearing, but coordination with downstream RCDs needs selectivity analysis — an instantaneous 30 mA unit will trip before a time-delayed 300 mA at the submain.

This is an outgoer device — it protects a final subcircuit, not the main incomer. The clip-on mounting attaches directly to the right side of an iC60 MCB, sharing the same DIN-rail footprint. The tunnel-type terminals at the bottom accept 1 to 35 mm² rigid cable (or 1 to 25 mm² flexible with/without ferrule), tightened to 3.5 N·m. The bottom connection also accepts comb busbars, so multiple Vigi iC60 units can be fed from a common distribution bar. IP20 rated for the device body; IP40 when enclosed in a modular enclosure per IEC 60529.