Skip to main content
Schneider Electric A9W25363

A9W25363 Acti9 Vigi iC60 RCD, 3P 63A 300mA Type A Selective

MPN A9W25363
Obsolete

Schneider Electric Acti9 Vigi iC60, add-on residual current device, 3P, 63 A, 300 mA, Type A selective, DIN rail clip-on.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9W25363 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage400 V AC 50/60 Hz conforming to EN 61009-1 400/415 V AC 50/60 Hz conforming to IEC 61009-1
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-2
Depth74 mm
Width117 mm
Height91 mm
Operating temperature-25...60 °C

Product details

The A9W25363 is an add-on residual current device (RCD) from the Acti9 Vigi iC60 range. It clips onto the outgoing side of an iC60 miniature circuit breaker to provide earth-leakage protection. Rated 63 A with 300 mA sensitivity, Type A (pulsating DC and sinusoidal AC fault detection), with a selective (time-delayed) characteristic — meaning it coordinates with downstream RCDs by riding out transient earth faults, so only the faulted branch trips. Three-pole construction (3P) for 400 V AC three-phase networks at 50/60 Hz. Voltage-independent tripping technology — the RCD operates without needing an external power supply, relying on the fault current itself to trigger the mechanism.

Clip-on mounting onto DIN rail. The 117 mm width occupies 7 modules of 9 mm pitch — standard for a 3P RCD in the Acti9 system. Tunnel-type terminals accept 1–35 mm² rigid or 1–25 mm² flexible cable; tightening torque 3.5 N·m. Wire strip length 14 mm. IP20 finger-safe on the front, IP40 within a modular enclosure.

Rated insulation voltage 500 V AC, rated impulse withstand 6 kV — the insulation system holds up under surge conditions typical of industrial mains. The 8/20 µs impulse withstand of 3000 A on the residual current path means the RCD survives lightning-induced or switching transients without nuisance tripping or damage.

MPN
A9W25363