Schneider Electric A9W30225

Schneider A9W30225 Vigi iC60 RCBO, 2P 25A 10mA SI Type, Obso

MPN A9W30225
Obsolete

Schneider Electric Acti9 Vigi iC60, add-on residual current device, 2 poles, 25 A, 10 mA sensitivity, Type A-SI (Super Immunised), obsolete.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9W30225 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage230...240 V AC 50/60 Hz conforming to EN 61009-1 230...240 V AC 50/60 Hz conforming to IEC 61009-1
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-2
Depth74 mm
Width63 mm
Height91 mm
Operating temperature-25...60 °C

Product details

The instantaneous trip response (no intentional delay) makes it suited for circuits requiring rapid disconnection on earth fault, such as socket-outlet circuits in commercial or residential final distribution boards.

Rated operational voltage is 230...240 V AC at 50/60 Hz per EN/IEC 61009-1, so it is designed for standard single-phase (line-to-neutral) supplies in European and similar 230/400 V distribution systems. The 10 mA sensitivity is exceptionally low — typically reserved for circuits where a higher trip threshold could be hazardous (e.g., medical locations, wet areas, or equipment requiring enhanced personnel protection). The Type A-SI (Super Immunised) classification means the device will not trip spuriously on 50 Hz harmonics, 1 kHz switching supplies, or pulsed DC superimposed on the AC waveform, which is a common failure mode for standard Type A RCDs when feeding variable-speed drives, UPS systems, or LED drivers. The voltage-independent tripping mechanism ensures the RCD operates even if the line voltage is lost — the fault energy itself powers the trip, a critical safety feature for circuits where loss of neutral could otherwise disable protection. The add-on design means this block physically mounts to the load side of a compatible iC60 MCB via screw terminals, not as a standalone device. It occupies 3 x 9 mm pitches on the DIN rail — 27 mm total width — so it adds three module widths to the breaker assembly. The tunnel-type terminals accept 1...25 mm² rigid or 1...16 mm² flexible conductors, and the recommended tightening torque is 2 N·m.

The device is designed and certified to EN 61009-1 and IEC 61009-1, the standards for residual current operated circuit breakers with integral overcurrent protection (RCBOs). The pollution degree is 3 per IEC 60947-2, meaning it is suitable for environments with conductive or dry non-conductive pollution — typical of industrial control panels and distribution boards. The impulse current withstand is 3000 A at 8/20 µs waveform, confirming it can survive surge events without damage.

MPN
A9W30225