Schneider Electric A9W30225 — Residual Current Breakers (RCCB/RCBO)

Schneider A9W30225 Vigi iC60 RCBO, 2P 25A 10mA SI Type, Obso

MPNA9W30225
Obsolete

Schneider Electric Acti9 Vigi iC60, add-on residual current device, 2 poles, 25 A, 10 mA sensitivity, Type A-SI (Super Immunised), obsolete.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9W30225 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)10 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Local signalling / indicationTrip indicator
A9W30225 — Electrical Ratings
ParameterValue
Rated current (In)25 A
Rated operational voltage (Ue)230...240 V AC 50/60 Hz conforming to EN 61009-1 230...240 V AC 50/60 Hz conforming to IEC 61009-1
Poles description2P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to IEC 60947-2
Device location in systemOutgoer
A9W30225 — Identification
ParameterValue
Product nameActi9 Vigi iC60
Product / component typeAdd-on residual current device
Product range / familyActi9
Device short nameVigi iC60
A9W30225 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Width in 9 mm modules3
Terminal connectionsTunnel type terminals downside 1...25 mm² rigid Tunnel type terminals downside 1...16 mm² flexible
Wire stripping length14 mm
Terminal tightening torque2 N.m
Width63 mm
Height91 mm
Depth74 mm
A9W30225 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-2
A9W30225 — Approvals
ParameterValue
StandardsEN 61009-1 IEC 61009-1

Product details

The instantaneous trip response (no intentional delay) makes it suited for circuits requiring rapid disconnection on earth fault, such as socket-outlet circuits in commercial or residential final distribution boards.

Rated operational voltage is 230...240 V AC at 50/60 Hz per EN/IEC 61009-1, so it is designed for standard single-phase (line-to-neutral) supplies in European and similar 230/400 V distribution systems. The 10 mA sensitivity is exceptionally low — typically reserved for circuits where a higher trip threshold could be hazardous (e.g., medical locations, wet areas, or equipment requiring enhanced personnel protection). The Type A-SI (Super Immunised) classification means the device will not trip spuriously on 50 Hz harmonics, 1 kHz switching supplies, or pulsed DC superimposed on the AC waveform, which is a common failure mode for standard Type A RCDs when feeding variable-speed drives, UPS systems, or LED drivers. The voltage-independent tripping mechanism ensures the RCD operates even if the line voltage is lost — the fault energy itself powers the trip, a critical safety feature for circuits where loss of neutral could otherwise disable protection. The add-on design means this block physically mounts to the load side of a compatible iC60 MCB via screw terminals, not as a standalone device. It occupies 3 x 9 mm pitches on the DIN rail — 27 mm total width — so it adds three module widths to the breaker assembly. The tunnel-type terminals accept 1...25 mm² rigid or 1...16 mm² flexible conductors, and the recommended tightening torque is 2 N·m.

The device is designed and certified to EN 61009-1 and IEC 61009-1, the standards for residual current operated circuit breakers with integral overcurrent protection (RCBOs). The pollution degree is 3 per IEC 60947-2, meaning it is suitable for environments with conductive or dry non-conductive pollution — typical of industrial control panels and distribution boards. The impulse current withstand is 3000 A at 8/20 µs waveform, confirming it can survive surge events without damage.

Frequently asked questions

What is the A9W30225 used for?

It is an add-on residual current device (RCD) for the Acti9 iC60 MCB range, providing 10 mA earth leakage protection (Type A-SI, Super Immunised) on 2-pole, 25 A circuits at 230-240 V AC. It is typically used in final distribution boards for socket-outlet circuits requiring enhanced personnel protection, such as in commercial, residential, or light industrial installations.