Skip to main content
Schneider Electric A9W31363

A9W31363 Acti9 Vigi iC60 3P 63A 30mA RCD, Type A-SI

MPN A9W31363
Active

Schneider Electric Acti9 Vigi iC60, add-on residual current device, 3P, 63 A, 30 mA, Type A-SI, instantaneous, 400/415 V AC, clip-on DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9W31363 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage400/415 V AC 50/60 Hz conforming to IEC 61009-1
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-2
Depth74 mm
Width117 mm
Height91 mm
Operating temperature-25...60 °C

Product details

The Schneider Electric A9W31363 is an add-on residual current device (RCD) from the Acti9 Vigi iC60 range, designed to snap onto the side of an iC60 miniature circuit breaker (MCB) via the clip-on mounting. It provides earth-leakage protection for the downstream circuit, tripping the MCB when leakage exceeds the 30 mA threshold. The 63 A rated current matches the MCB it attaches to, so the pair handles the full load current of the circuit. The Type A-SI (Super Immunised) classification means it detects sinusoidal AC and pulsating DC residual currents, while being immune to nuisance tripping from high-frequency harmonics or transient surges — a requirement for circuits feeding electronic loads like VFDs, UPS systems, or IT equipment. The voltage-independent tripping technology ensures the RCD operates even if the line voltage is lost, which is a safety advantage over electronically dependent units.

The 117 mm width, 91 mm height, and 74 mm depth fit within the standard Acti9 modular enclosure footprint. The electrical connection to the MCB is via screws, so the assembly is mechanical and electrical — no extra wiring between the two devices. The IP20 rating (IP40 in modular enclosure) is suitable for dry indoor panel environments; pollution degree 3 per IEC 60947-2 covers the typical industrial panel atmosphere.

The device is designed and certified to IEC 61009-1 and EN 61009-1, the governing standards for residual current operated circuit breakers with integral overcurrent protection (RCBOs) — though this is an add-on RCD, not a combined unit, the standard applies to the residual current function. The 8/20 µs impulse withstand rating of 3000 A per IEC 61009-1 confirms it survives common surge events without damage. The local trip indicator provides visual confirmation of a residual current trip, aiding fault isolation.

MPN