Schneider Electric A9W35363

A9W35363 Acti9 Vigi iC60 RCD, 3P 63A 300mA A-SI Selective

MPN A9W35363
Active

Schneider Electric Acti9 Vigi iC60 add-on residual current device, A9W35363, 3P, 63 A, 300 mA, Type A-SI selective, 400 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9W35363 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage400 V AC 50/60 Hz conforming to EN 61009-1 230/415 V AC 50/60 Hz conforming to IEC 61009-1
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-2
Depth74 mm
Width117 mm
Height91 mm
Operating temperature-25...60 °C

Product details

The Schneider Electric A9W35363 is an Acti9 Vigi iC60 add-on residual current device — 3 poles, rated 63 A, with a 300 mA earth-leakage sensitivity. It clips onto the outgoing side of an iC60 MCB via the screw connection, adding RCD protection to that circuit without replacing the breaker. The Type A-SI (Super Immunised) classification means it handles pulsed DC fault currents from electronics (VSDs, UPS, LED drivers) that would desensitize a standard Type A, while the selective time delay (short intentional delay) coordinates with downstream RCDs so only the faulted subcircuit trips — critical for a distribution board feeding multiple loads where nuisance tripping on a main RCD shuts the whole panel.

63 A rated current matches the iC60 breaker it pairs with — the RCD does not increase the circuit ampacity, it just adds leakage detection. The 300 mA sensitivity is typical for main or submain protection where a 30 mA unit would nuisance-trip on normal cable leakage. Selective (S-type) delay gives about 40–150 ms inertia, letting downstream 30 mA RCDs clear first. Voltage-independent tripping means it operates even if the neutral is lost — the fault energy itself triggers the mechanism, no auxiliary supply needed. The 400 V AC rated operational voltage (per EN 61009-1) covers 3-phase 4-wire networks up to 415 V line-to-line.

Clip-on mounting to DIN rail, 7 x 9 mm pitches wide (117 mm). The tunnel-type terminals accept up to 35 mm² rigid or 25 mm² flexible cable, with a 3.5 N.m tightening torque and 14 mm strip length. The trip indicator gives local visual confirmation of a leakage trip, which speeds troubleshooting on a multi-circuit panel.

MPN
A9W35363