Skip to main content
Schneider Electric ATV1200A15606060

Schneider Electric ATV1200A15606060 AC Drive, 1304 kW

MPN ATV1200A15606060
Active

Schneider Electric Altivar 1200 series, ATV1200A15606060 AC drive, 1304 kW motor power, 1560 kVA apparent power, 30-pulse diode rectifier, 2970-3630 V supply, floor-standing enclosure.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV1200A15606060 specifications
ParameterValue
Input type30 pulse diode rectifier bridge
Protection typeGround fault protection: drive
Coil voltage220 V
Current150 A
IP ratingIP41 / IP42 / IP31
Temp storage max60 °C
Temp storage min-10 °C
Temp operating max50 °C
Temp operating min0 °C
Storage temperature-10...60 °C
Pollution degreePollution degree 2
Depth1600 mm (high efficiency) 1500 mm (standard efficiency)
Width3960 mm (high efficiency) 3660 mm (standard efficiency)
Height2820 mm standard efficiency 2820 mm high efficiency
Operating positionVertical +/- 10 degree
Operating temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)

Product details

Active production — what that means for procurement

The ATV1200A15606060: No stock-holding claim — quoted per BOM.

1304 kW motor drive — load profile and harmonic mitigation

Rated for 1304 kW motor power at 1560 kVA apparent power, with a 30-pulse diode rectifier input stage. The 30-pulse topology cancels the 5th, 7th, 11th, 13th, 17th, and 19th harmonics at the input, keeping total harmonic distortion low enough to meet IEEE 519 without a separate active filter in most installations. Supply voltage range is 2970-3630 V — this is a medium-voltage drive, not a 480 V unit. The output voltage tracks the supply (≤ supply voltage), so motor winding insulation must be rated for the full DC bus potential. Line current draw is 150 A at rated load.

Overload capability and cooling — sizing for the duty cycle

Two overload profiles are available: standard overload allows 1.2× In for 60 seconds and 1.5× In for 3 seconds; high overload allows 1.5× In for 60 seconds and 1.85× In for 3 seconds. The high-overload setting is the one to use for heavy-start loads like crushers or extruders — standard overload is adequate for centrifugal pumps and fans. Cooling is forced convection with separate air flows for the transformer and power cells. The standard-efficiency configuration moves 29,900 m³/h of air; the high-efficiency version moves 33,200 m³/h. Ambient temperature and altitude derating apply — above 1000 m, derate current 0.6 % per 100 m.

Physical footprint and installation constraints

Floor-standing enclosure with separate air flows for the transformer and power cells. The standard-efficiency variant measures 3660 mm wide × 2820 mm high × 1500 mm deep; the high-efficiency variant is 3960 mm wide × 2820 mm high × 1600 mm deep. Operating position is vertical ±10 degrees — no side-mount or horizontal installation.

Compliance and isolation — standards coverage

CE marked, with compliance to EN/IEC 60204-11 (electrical equipment of machines), EN/IEC 60529 (enclosure protection), EN/IEC 61800-3 (EMC for drive systems), EN/IEC 61800-4 (drive performance), and EN/IEC 61800-5-1 (electrical safety). Pollution degree 2 per EN/IEC 61800-5-1 — suitable for controlled environments with non-conductive pollution. Electrical isolation between power and control circuits, with a dielectric strength of 20 kV AC between earth and power terminals. Overvoltage category II per EN/IEC 61800-5-1. Ground fault protection is integral to the drive.

MPN
ATV1200A15606060