Skip to main content
Schneider Electric ATV1200A20806060

Schneider Electric ATV1200A20806060 AC Drive, 1739 kW

MPN ATV1200A20806060
Active

Schneider Electric Altivar 1200 AC drive, ATV1200A20806060, 1739 kW motor power, 2080 kVA apparent power, 30-pulse diode rectifier input, 2970-3630 V supply, floor-standing enclosure.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV1200A20806060 specifications
ParameterValue
Input type30 pulse diode rectifier bridge
Protection typeGround fault protection: drive
Coil voltage220 V
Current200 A
IP ratingIP42 / IP41 / IP31
Temp storage max60 °C
Temp storage min-10 °C
Temp operating max50 °C
Temp operating min0 °C
Storage temperature-10...60 °C
Pollution degreePollution degree 2
Depth1500 mm (standard efficiency) 1700 mm (high efficiency)
Width4660 mm (standard efficiency) 4960 mm (high efficiency)
Height2670 mm high efficiency 2670 mm standard efficiency
Operating positionVertical +/- 10 degree
Operating temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)

Product details

The ATV1200A20806060 is a medium-voltage Altivar 1200 drive rated for 1739 kW motor power and 2080 kVA apparent power, fed from a 2970...3630 V supply through a 30-pulse diode rectifier bridge. The 30-pulse topology cancels the 5th, 7th, 11th, 13th, 17th, and 19th harmonics at the input — you can size the upstream transformer without the usual 30% derating for VFD harmonic content. Overload capability is published as two duty profiles: standard overload holds 1.2 x In for 60 s and 1.5 x In for 3 s; high overload holds 1.5 x In for 60 s and 1.85 x In for 3 s. The high-overload curve is the one to use for extruder or crusher starts where the breakaway torque exceeds 150% for several seconds.

Construction and integration constraints

The drive ships in a floor-standing enclosure with separate air flows for the power cells and the phase-shifting transformer. The enclosure footprint is substantial: standard-efficiency units measure 4660 mm wide x 1500 mm deep x 2670 mm high; high-efficiency variants add 300 mm to the width and 200 mm to the depth. Plan the substation floor layout around these dimensions before the unit arrives. Cooling is forced convection pulling 23,100 m³/h of air through the cabinet. The noise level at full fan speed is 80 dB — that is a hearing-protection zone inside the switchroom, not a quiet corner. The cooling fan supply is 380 V AC internal; an optional external 380 V fan supply is available for maintenance bypass.

CE marked and designed to EN/IEC 61800-3 (EMC environment), EN/IEC 61800-4 (thermal), and EN/IEC 61800-5-1 (electrical safety, pollution degree 2, overvoltage category II). The dielectric strength between power terminals and earth is 20 kV AC — a figure that matches the medium-voltage insulation coordination for a 3.3 kV class drive. The drive withstands a prospective line short-circuit current of 31.5 kA for 150 ms. This lets the upstream protection coordinate without an extra current-limiting reactor in most 3.3 kV distribution systems.

MPN
ATV1200A20806060