Schneider Electric ATV1200A20806060 — AC Drive (VFD) 480V

Schneider Electric ATV1200A20806060 AC Drive, 1739 kW

MPNATV1200A20806060
Active

Schneider Electric Altivar 1200 AC drive, ATV1200A20806060, 1739 kW motor power, 2080 kVA apparent power, 30-pulse diode rectifier input, 2970-3630 V supply, floor-standing enclosure.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV1200A20806060 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A20806060 — Power & Output
ParameterValue
Motor power (kW)1739 kW
Continuous output current200 A (standard overload) 160 A (high overload)
Max. transient current240 A for 60 s
Apparent power2080 kVA

Input / Supply

ATV1200A20806060 — Input / Supply
ParameterValue
Rated supply voltage range6 kV +/- 10 %
Input line current200 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A20806060 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesSensorless flux vector control Voltage/frequency ratio (V/f) Vector control with sensor, optional Closed-loop control with encoder
Synchronous motor control modesClosed-loop control with encoder Voltage/frequency ratio (V/f)

Protection & EMC

ATV1200A20806060 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A20806060 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP42 IP41 IP31
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A20806060 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A20806060 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A20806060 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

The ATV1200A20806060 is a medium-voltage Altivar 1200 drive rated for 1739 kW motor power and 2080 kVA apparent power, fed from a 2970...3630 V supply through a 30-pulse diode rectifier bridge. The 30-pulse topology cancels the 5th, 7th, 11th, 13th, 17th, and 19th harmonics at the input — you can size the upstream transformer without the usual 30% derating for VFD harmonic content. Overload capability is published as two duty profiles: standard overload holds 1.2 x In for 60 s and 1.5 x In for 3 s; high overload holds 1.5 x In for 60 s and 1.85 x In for 3 s. The high-overload curve is the one to use for extruder or crusher starts where the breakaway torque exceeds 150% for several seconds.

Construction and integration constraints

The drive ships in a floor-standing enclosure with separate air flows for the power cells and the phase-shifting transformer. The enclosure footprint is substantial: standard-efficiency units measure 4660 mm wide x 1500 mm deep x 2670 mm high; high-efficiency variants add 300 mm to the width and 200 mm to the depth. Plan the substation floor layout around these dimensions before the unit arrives. Cooling is forced convection pulling 23,100 m³/h of air through the cabinet. The noise level at full fan speed is 80 dB — that is a hearing-protection zone inside the switchroom, not a quiet corner. The cooling fan supply is 380 V AC internal; an optional external 380 V fan supply is available for maintenance bypass.

CE marked and designed to EN/IEC 61800-3 (EMC environment), EN/IEC 61800-4 (thermal), and EN/IEC 61800-5-1 (electrical safety, pollution degree 2, overvoltage category II). The dielectric strength between power terminals and earth is 20 kV AC — a figure that matches the medium-voltage insulation coordination for a 3.3 kV class drive. The drive withstands a prospective line short-circuit current of 31.5 kA for 150 ms. This lets the upstream protection coordinate without an extra current-limiting reactor in most 3.3 kV distribution systems.

Frequently asked questions

What motor types does this drive support?

It is rated for both synchronous and asynchronous motors. The 30-pulse input and integrated EMC filter make it suitable for applications where low line-side harmonics and conducted emissions are specified.