Skip to main content
Schneider Electric ATV1200A4704242

Schneider Electric ATV1200A4704242 Altivar 1200, 393 kW

MPN ATV1200A4704242
Active

Schneider Electric Altivar 1200 series, ATV1200A4704242 medium voltage drive, 393 kW, 470 kVA, 24-pulse rectifier, 2970-3630 V supply, floor-standing enclosure.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV1200A4704242 specifications
ParameterValue
Input type24 pulse diode rectifier bridge
Protection typeGround fault protection: drive
Coil voltage220 V
Current65 A
IP ratingIP41 / IP42 / IP31
Temp storage max60 °C
Temp storage min-10 °C
Temp operating max50 °C
Temp operating min0 °C
Storage temperature-10...60 °C
Pollution degreePollution degree 2
Depth1400 mm (standard efficiency) 1500 mm (high efficiency)
Width2660 mm (standard efficiency) 2960 mm (high efficiency)
Height2520 mm standard efficiency 2670 mm high efficiency
Operating positionVertical +/- 10 degree
Operating temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)

Product details

What the 24-pulse input buys you on harmonics

The ATV1200A4704242: The 24-pulse diode rectifier bridge (cite:) cancels the 5th, 7th, 11th, and 13th harmonics at the input — you stay below IEEE 519 distortion limits without an external filter. The integrated EMC filter (cite:) handles the conducted emissions side. For a site with a weak grid or multiple drives on the same transformer, this saves the cost of a separate harmonic trap cabinet. Apparent power is 470 kVA (cite:), line current 65 A (cite:). The prospective short-circuit current rating is 31.5 kA for 150 ms (cite:) — the drive's input stage can ride through a fault on the primary side without the upstream breaker clearing first. Dielectric strength between earth and power terminals is 20 kV AC (cite:), which covers the transient overvoltages expected on a medium-voltage bus. Overload capability is specified in two duty bands: 1.2× rated current for 60 s (standard overload) or 1.5× for 3 s; the high-overload profile gives 1.5× for 60 s and 1.85× for 3 s (cite:). That second band matters if the driven load — a crusher, centrifuge, or conveyor with a high breakaway torque — needs extra current during acceleration.

Floor-standing enclosure — what fits through the door

The drive ships in a floor-standing enclosure with separate air flows for the power section and the control electronics (cite:). Standard-efficiency configuration: 1400 mm deep, 2660 mm wide, 2520 mm high (cite:,). High-efficiency option adds 100 mm to depth, 300 mm to width, and 150 mm to height. Cooling airflow is 9900 m³/h standard, 13200 m³/h high-efficiency (cite:) — plan the room ventilation around that exhaust volume. Operating altitude range is 1000-2000 m with a 0.6% current derating per 100 m above 1000 m (cite:). The 80 dB noise level (cite:) means ear protection in the drive room is mandatory — not a surprise for an MV drive, but worth flagging for the site acoustics plan.

CE marked (cite:). Designed to EN/IEC 60204-11 (safety of machinery — MV equipment), EN/IEC 60529 (enclosure protection), EN/IEC 61800-3 (EMC for adjustable-speed drives), EN/IEC 61800-4 (voltage-source drives), and EN/IEC 61800-5-1 (electrical, thermal, and energy safety) (cite:). Pollution degree 2 per EN/IEC 61800-5-1 (cite:), overvoltage category II (cite:). The compliance package covers the machinery directive and the EMC directive for industrial environments.

MPN