Skip to main content
Schneider Electric ATV350U40N4FS

Schneider Electric ATV350U40N4FS Altivar Machine ATV350, 4 k

MPN ATV350U40N4FS
Active

Schneider Electric Altivar Machine ATV350, ATV350U40N4FS, 4 kW / 14 A, 3-phase 400-480 V, integrated C2 EMC filter, STO, EtherNet/IP.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV350U40N4FS specifications
ParameterValue
Main product or component typeVariable speed drive
Voltage460 V
Current14 A 400...480 V conveying applications)
Output current14 A
Frequency45...65 Hz
Temp storage max60 °C
Temp storage min-30 °C
Temp operating max60 °C
Temp operating min-30 °C
Storage temperature-22...140 °F (-30...60 °C)
Pollution degree2
Depth9.2 in (233 mm)
Width20.6 in (522 mm)
Height12.2 in (310 mm)
Operating positionHorizontal
Discrete input logicProgrammable digital input digital I/O, 0...0.8 V, 11...24 V

Product details

The Schneider Electric ATV350U40N4FS is an Altivar Machine ATV350 drive sized for a 4 kW asynchronous or synchronous motor on 400-480 V three-phase supply. Output current is 14 A continuous, with a 1-599 Hz output frequency range. An integrated Class C2 EMC filter covers 10 m cable runs, keeping external filter costs off the BOM for most panel builds. STO (Safe Torque Off) is built in per IEC 61800-5-2, so no separate safety relay is needed for a controlled stop on a machine cell. The drive carries CE, UL, CULus, and UKCA marking, with compliance to IEC 61800-5-1, UL 508C, and IEC 61508.

Fieldbus and I/O

Two Ethernet ports support EtherNet/IP, Modbus TCP, PROFINET, and EtherCAT via M12 I/O on the base. The internal 24 V DC supply powers the logic inputs, and a programmable digital input accepts 11-24 V logic. An incremental encoder input (24 V) is available for closed-loop speed feedback.

Protection and derating

Protection covers line supply phase loss, motor phase loss, overvoltage/undervoltage, overheating, motor overload (with PTC probes), short-circuit between motor phases, and overcurrent between output phases and earth. Switching frequency is adjustable 2-16 kHz; derate current 0.5% per 100 m above 1000 m altitude. For 3-phase input, derate current 2.5% per °C above 40 °C ambient.