Skip to main content
Schneider Electric ATV350U40N4FS — AC Drive (VFD) 480V

Schneider Electric ATV350U40N4FS Altivar Machine ATV350, 4 k

MPNATV350U40N4FS
Active

Schneider Electric Altivar Machine ATV350, ATV350U40N4FS, 4 kW / 14 A, 3-phase 400-480 V, integrated C2 EMC filter, STO, EtherNet/IP.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV350U40N4FS — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV350
Product range / familyAltivar Machine ATV350
ATV350U40N4FS — Power & Output
ParameterValue
Motor power (kW)4 kW conveying applications
Continuous output current14 A 2...16 kHz conveying applications
Max. transient current28 A 3 s conveying applications) 21 A 60 s conveying applications)
Apparent power5.9 kVA 400...480 V conveying applications)
ATV350U40N4FS — Input / Supply
ParameterValue
Rated supply voltage range400...480 V +/-5 %
Input line current14 A 400...480 V conveying applications)
Internal/auxiliary suppliesInternal supply for logic inputs 24 V DC
ATV350U40N4FS — Control & Performance
ParameterValue
Asynchronous motor control modesU/F vector control Sensorless vector control (SVC) Energy saving control Closed-loop control with encoder
Synchronous motor control modesPermanent magnet control in open loop Permanent magnet control in close loop
ATV350U40N4FS — Protection & EMC
ParameterValue
Integrated EMC filter classClass C2 EMC filter integrated EN 61508 32.8 ft (10 m) Class C2 EMC filter integrated EN 61800-5-1 32.8 ft (10 m) Class C2 EMC filter integrated EN 61800-5-2 32.8 ft (10 m) Class C2 EMC filter integrated IEC 60529 32.8 ft (10 m) Class C2 EMC filter integrated UL 50E 32.8 ft (10 m) Class C2 EMC filter integrated machinery directive 2006/42/EC 32.8 ft (10 m)
Protection functionsLine supply phase loss drive Motor phase loss motor Line supply overvoltage and undervoltage drive Overheating protection drive Overload motor With PTC probes motor Short-circuit between motor phases drive Overcurrent between output phases and earth drive
ATV350U40N4FS — Mechanical & Cooling
ParameterValue
IP degree of protectionIP54 conforming to EN 61508 IP54 conforming to EN 61800-5-1 IP54 conforming to EN 61800-5-2 IP54 conforming to IEC 60529 IP54 conforming to UL 50E IP54 conforming to machinery directive 2006/42/EC
Cooling methodAN (air natural)
ATV350U40N4FS — Environmental
ParameterValue
Operating ambient temperature-22...140 °F (-30...60 °C) (with current derating of 2.5 % per °C above 40 °C)
Operating altitude3280.84 ft (1000 m) with current derating of 0.5 % per additional 100 m
Relative humidity5...95 % without condensation EN/IEC 60068-2-3
Storage / transport temperature-22...140 °F (-30...60 °C)
Pollution degree2
Vibration resistance1 mm (f= 5...13 Hz) conforming to DNVGL-GC-0339 0.7 gn (f= 13...100 Hz) conforming to DNVGL-GC-0339
ATV350U40N4FS — Approvals
ParameterValue
Certifications & markingCE UL CULus IEC UKCA
Standards complianceIEC 61800-5-1 IEC 61800-3 UL 508C IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 2 category C3 IEC 60721-3 IEC 61508 IEC 13849-1
ATV350U40N4FS — Communication
ParameterValue
Communication protocolsEtherNet/IP EtherCAT IO-Link Modbus TCP PROFINET

Product details

The Schneider Electric ATV350U40N4FS is an Altivar Machine ATV350 drive sized for a 4 kW asynchronous or synchronous motor on 400-480 V three-phase supply. Output current is 14 A continuous, with a 1-599 Hz output frequency range. An integrated Class C2 EMC filter covers 10 m cable runs, keeping external filter costs off the BOM for most panel builds. STO (Safe Torque Off) is built in per IEC 61800-5-2, so no separate safety relay is needed for a controlled stop on a machine cell. The drive carries CE, UL, CULus, and UKCA marking, with compliance to IEC 61800-5-1, UL 508C, and IEC 61508.

Fieldbus and I/O

Two Ethernet ports support EtherNet/IP, Modbus TCP, PROFINET, and EtherCAT via M12 I/O on the base. The internal 24 V DC supply powers the logic inputs, and a programmable digital input accepts 11-24 V logic. An incremental encoder input (24 V) is available for closed-loop speed feedback.

Protection and derating

Protection covers line supply phase loss, motor phase loss, overvoltage/undervoltage, overheating, motor overload (with PTC probes), short-circuit between motor phases, and overcurrent between output phases and earth. Switching frequency is adjustable 2-16 kHz; derate current 0.5% per 100 m above 1000 m altitude. For 3-phase input, derate current 2.5% per °C above 40 °C ambient.

Frequently asked questions

What safety functions does this drive include?

It includes STO (Safe Torque Off) per IEC 61800-5-2, eliminating the need for a separate safety relay for controlled stops.

What certifications does the ATV350U40N4FS carry?

It carries CE, UL, CULus, and UKCA marking, with compliance to IEC 61800-5-1, UL 508C, IEC 61508, and IEC 13849-1.

What fieldbus interfaces are available?

Two Ethernet ports support EtherNet/IP, Modbus TCP, PROFINET, and EtherCAT via M12 connectors on the base.

MPN