Specifications

ATV6000C100A6666NA3 specifications
ParameterValue
Input type30 pulse diode rectifier bridge
Display type10 inch LCD touch screen multi-language
Connector type2 RJ45 (on the control block) for Ethernet IP/Modbus TCP 1 RJ45 (on the control block) for Modbus serial
Current87.5 A normal duty 83 A heavy duty
Frequency50 Hz +/- 5 %
IP ratingIP31
Temp storage max50 °C
Temp storage min0 °C
Temp operating max60 °C
Temp operating min1.2 °C
Storage temperature0...50 °C
Pollution degree2 conforming to IEC 61800-5-1
Depth1400 mm
Width3060 mm
Height2617 mm
Operating temperature0...40 °C 40...50 °C with derating factor -25...70 °C during transport

Product details

800 kW in a 30-pulse topology

The Schneider Electric ATV6000C100A6666NA3 is an Altivar Process ATV6000 AC drive rated 800 kW for normal duty and 760 kW for heavy duty, with a 30-pulse diode rectifier front end that holds input current THDI below 3% per IEEE 519:1992 without external filters.

Multilevel PWM and harmonic compliance

Output uses IGBT inverter cells in a multilevel PWM topology; the 30-pulse input bridge delivers a power factor of 96% and line current draw of 87.5 A normal duty / 83 A heavy duty. Integrated EMC filter meets IEC 61800-3 category C3 on the control side and C4 on the power side, which means the drive is intended for industrial environments with a dedicated transformer or isolation — not direct connection to a public low-voltage grid without additional mitigation. Power losses are 34.9 kW at normal duty and 33.1 kW at heavy duty; the forced-convection cooling system and the 80 dB noise level should be factored into the equipment room HVAC and acoustic planning.

Floor-standing enclosure and integration

The drive ships in a floor-standing enclosure (3060 mm wide × 2617 mm high × 1400 mm deep) complete with power cells, phase-shifting transformer, cooling fans, HMI, medium voltage arrestors, and plinth — a near-turnkey power section that needs only incoming supply and motor cables at the bottom cable entry. Two option card slots (Slot A and Slot B) accept fieldbus modules (Profibus DP V1, PROFINET, DeviceNet, CANopen, EtherCAT) and encoder feedback interfaces (digital, analog, resolver, HTL), so the drive integrates into most automation architectures without a separate gateway.