Specifications

ATV6000C100A6666NA3 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV6000
Product range / familyAltivar Process ATV6000
ATV6000C100A6666NA3 — Power & Output
ParameterValue
Motor power (kW)800 kW for normal duty 760 kW for heavy duty
Continuous output current83.7 A normal duty 80 A heavy duty
Max. transient current126 A during 3 s (normal duty) 150 A during 3 s (heavy duty)
Apparent power1000 kVA
ATV6000C100A6666NA3 — Input / Supply
ParameterValue
Rated supply voltage range6.6 kV +/- 10 %
Input line current87.5 A normal duty 83 A heavy duty
Network number of phases3 phases
Internal/auxiliary suppliesInternal supply for digital inputs and PoE 24 V DC 21...27 V, Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, External supply for digital inputs 24 V DC 19...30 V External supply for control circuit 100...240 V AC 47...63 Hz External supply for control circuit 120...370 V DC +/- 10 % 1 kVA Auxiliary power supply 230 V AC +/- 10 % External supply for cooling fan 400 V AC +/- 10 % 7 kVA
ATV6000C100A6666NA3 — Control & Performance
ParameterValue
Output frequency range0.1...120 Hz
Asynchronous motor control modesClosed loop vector control U/F vector control Energy saving control Vector control with slip compensation in open loop
Synchronous motor control modesPermanent magnet control in open loop Permanent magnet control in close loop Line start permanent magnet motor
ATV6000C100A6666NA3 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated conforming to IEC 61800-3 category C3 control Integrated conforming to IEC 61800-3 category C4 power
Protection functionsLine supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overvoltages on the DC bus: drive Thermal overload for transformer: drive Cabinet overheating: drive Overcurrent: drive Overload: drive Short-circuit protection: drive IGBT for each cell: drive Thermal protection: motor Motor phase break: motor Motor earth fault: motor Break on the control circuit: drive Fan monitoring: drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)31.5 kA for 150 ms
ATV6000C100A6666NA3 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP31 conforming to IEC 60529
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure
ATV6000C100A6666NA3 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C with derating factor -25...70 °C during transport
Operating altitude1000...2000 m with derating factor
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Storage / transport temperature0...50 °C
Pollution degree2 conforming to IEC 61800-5-1
ATV6000C100A6666NA3 — Approvals
ParameterValue
Certifications & markingCE EAC
Standards complianceIEC 61800-3 EN/IEC 61800-4 IEC 61800-5-1 IEC 60529 IEEE 519:1992 EN/IEC 60076
ATV6000C100A6666NA3 — Communication
ParameterValue
Communication protocolsEthernet IP/Modbus TCP

Product details

800 kW in a 30-pulse topology

The Schneider Electric ATV6000C100A6666NA3 is an Altivar Process ATV6000 AC drive rated 800 kW for normal duty and 760 kW for heavy duty, with a 30-pulse diode rectifier front end that holds input current THDI below 3% per IEEE 519:1992 without external filters.

Multilevel PWM and harmonic compliance

Output uses IGBT inverter cells in a multilevel PWM topology; the 30-pulse input bridge delivers a power factor of 96% and line current draw of 87.5 A normal duty / 83 A heavy duty. Integrated EMC filter meets IEC 61800-3 category C3 on the control side and C4 on the power side, which means the drive is intended for industrial environments with a dedicated transformer or isolation — not direct connection to a public low-voltage grid without additional mitigation. Power losses are 34.9 kW at normal duty and 33.1 kW at heavy duty; the forced-convection cooling system and the 80 dB noise level should be factored into the equipment room HVAC and acoustic planning.

Floor-standing enclosure and integration

The drive ships in a floor-standing enclosure (3060 mm wide × 2617 mm high × 1400 mm deep) complete with power cells, phase-shifting transformer, cooling fans, HMI, medium voltage arrestors, and plinth — a near-turnkey power section that needs only incoming supply and motor cables at the bottom cable entry. Two option card slots (Slot A and Slot B) accept fieldbus modules (Profibus DP V1, PROFINET, DeviceNet, CANopen, EtherCAT) and encoder feedback interfaces (digital, analog, resolver, HTL), so the drive integrates into most automation architectures without a separate gateway.

Frequently asked questions

Where can I buy the ATV6000C100A6666NA3 and get a price?

Sourced to order against your BOM quantity through independent distribution.

What does the 30-pulse rectifier mean for harmonic compliance?

The 30-pulse diode bridge keeps input current total harmonic distortion (THDI) below 3% per IEEE 519:1992, which typically eliminates the need for external harmonic filters on the line side.