Skip to main content
Schneider Electric ATV6000C742A1010NA3

Schneider ATV6000C742A1010NA3 Altivar Process Drive, 7420 kV

MPN ATV6000C742A1010NA3
Active

Schneider Electric Altivar Process ATV6000, ATV6000C742A1010NA3, 7420 kVA, 48-pulse diode rectifier, floor-standing enclosure.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV6000C742A1010NA3 specifications
ParameterValue
Input type48 pulse diode rectifier bridge
Display type10 inch LCD touch screen multi-language
Connector type2 RJ45 (on the control block) for Ethernet IP/Modbus TCP 1 RJ45 (on the control block) for Modbus serial
Current340 A heavy duty 428 A normal duty
Frequency50 Hz +/- 5 %
IP ratingIP31
Temp storage max50 °C
Temp storage min0 °C
Temp operating max60 °C
Temp operating min1.2 °C
Storage temperature0...50 °C
Pollution degree2 conforming to IEC 61800-5-1
Depth1800 mm
Width8860 mm
Height3151 mm
Operating temperature0...40 °C 40...50 °C with derating factor -25...70 °C during transport

Product details

Supply and footprint

The ATV6000C742A1010NA3: The drive requires a 50 Hz supply (50 Hz +/- 5 %) and draws 340 A heavy duty or 428 A normal duty line current. Input THDI is under 3 % conforming to IEEE 519-1992, achieved by the 48-pulse rectifier. The floor-standing enclosure measures 8860 mm wide by 1800 mm deep by 3151 mm high — plan the substation bay accordingly.

Control and I/O

The control block provides 2 RJ45 ports for Ethernet IP/Modbus TCP and 1 RJ45 for Modbus serial. Slot A accepts fieldbus modules for Profibus DP V1, PROFINET, DeviceNet, CANopen (RJ45, SUB-D 9, or screw terminals), or EtherCAT. Slot B takes encoder interface modules (5/12 V digital, analog, resolver, HTL). Both slots can host digital/analog I/O extension or output relay extension modules. The 10-inch LCD touch screen multi-language display is standard.

Protection and compliance

Protection covers line supply overvoltage/undervoltage/phase loss, DC bus overvoltage, transformer thermal overload, cabinet overheating, overcurrent, overload, short-circuit, IGBT cell faults, motor thermal/phase/earth faults, control circuit break, and fan monitoring. The drive carries CE and EAC marking and conforms to IEC 61800-3, IEC 61800-4, IEC 61800-5-1, IEC 60529, IEEE 519:1992, and EN/IEC 60076. The integrated EMC filter meets IEC 61800-3 category C3 on the control side and C4 on the power side.

Provided equipment

The drive ships with plinth, medium-voltage arrestors, human-machine interface, enclosure, cooling fans, phase-shifting transformer, and power cells.

MPN
ATV6000C742A1010NA3