Skip to main content
Schneider Electric ATV6000D690A1111NA3

ATV6000D690A1111NA3 Altivar Process ATV6000, 550 kW ND drive

MPN ATV6000D690A1111NA3
Active

Schneider Electric Altivar Process ATV6000, ATV6000D690A1111NA3, medium-voltage drive, 550 kW normal duty / 440 kW heavy duty, 690 kVA, floor-standing enclosure.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV6000D690A1111NA3 specifications
ParameterValue
Input type54 pulse diode rectifier bridge
Current29 A heavy duty 36.3 A normal duty
Frequency50 Hz +/- 5 %
IP ratingIP31
Temp storage max50 °C
Temp storage min0 °C
Temp operating max60 °C
Temp operating min1.2 °C
Storage temperature0...50 °C
Pollution degree2 conforming to IEC 61800-5-1
Depth1600 mm
Width3860 mm
Height2751 mm

Product details

The ATV6000D690A1111NA3 is a medium-voltage drive from the Altivar Process ATV6000 range, built into a floor-standing enclosure. It's sized for permanent-magnet, asynchronous, or synchronous motors up to 550 kW under normal duty or 440 kW under heavy duty, with an apparent power rating of 690 kVA. Line current sits at 29 A for heavy duty and 36.3 A for normal duty. The 54-pulse diode rectifier bridge keeps input THDI below 3% per IEEE 519-1992, so you're not fighting harmonics from the start.

Power losses run 19.2 kW in heavy duty and 24 kW in normal duty, which drives the forced-convection cooling requirement and the 80 dB noise level; plan for that in a panel or room where sound matters. The integrated EMC filter meets IEC 61800-3 category C3 on the control side and C4 on the power side — that's a C4 industrial environment filter, so you're covered for the tougher conducted-emission limits without an add-on box.

Integration notes

Cable entry is at the bottom. The control block has two RJ45 ports for Ethernet IP / Modbus TCP and one RJ45 for Modbus serial. Option slots A and B accept communication modules (PROFIBUS, PROFINET, EtherCAT, DeviceNet, CANopen) and encoder interfaces (digital, analog, resolver, HTL). Three configurable relay outputs handle fault and sequence signaling. The 10-inch LCD touch screen is multi-language, so commissioning and diagnostics don't need a laptop. Supply for the control circuit can be 100–240 V AC or 120–370 V DC; the fan runs on a separate 400 V AC supply.

MPN